Search arXivSearch

arXiv · 1910.00348

SiPM behaviour under continuous light

Abstract

This paper reports on the behaviour of Silicon Photomultiplier (SiPM) detectors under continuous light. Usually, the bias circuit of a SiPM has a resistor connected in series to it, which protects the sensor from drawing too high current. This resistor introduces a voltage drop when a SiPM draws a steady current, when illuminated by constant light. This reduces the actual SiPM bias and then its sensitivity to light. As a matter of fact, this effect changes all relevant SiPM features, both electrical (i.e. breakdown voltage, gain, pulse amplitude, dark count rate and optical crosstalk) and optical (i.e. photon detection efficiency). To correctly operate such devices, it is then fundamental to calibrate them under various illumination levels. In this work, we focus on the large area ($\sim$1~cm$^{2}$) hexagonal SiPM S10943-2832(X) produced by Hamamatsu HPK for the camera of a gamma-ray telescope with 4 m-diameter mirror, called the SST-1M. We characterize this device under light rates raging from 3~MHz up to 5~GHz of photons per sensor at room temperature (T = 25 $^{\circ}$C). From these studies, a model is developed in order to derive the parameters needed to correct for the voltage drop effect. This model can be applied for instance in the analysis of the data acquired by the camera to correct for the effect. The experimental results are also compared with a toy Monte Carlo simulation and finally, a solution is proposed to compensate for the voltage drop.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A. Nagai, C. Alispach, D. della Volpe, M. Heller, T. Montaruli, S. Njoh, Y. Reniera, I. Troyano-Pujadas. 2019-11-25. SiPM behaviour under continuous light. https://doi.org/10.1088/1748-0221%2F14%2F12%2Fp12016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det