Search arXivSearch

arXiv · 1911.05190

Observation of Nanoscale Opto-Mechanical Molecular Damping; Origin of Spectroscopic Contrast in Photo Induced Force Microscopy

Abstract

We experimentally investigated the contrast mechanism of infrared photoinduced force microscopy (PiFM) for recording vibrational resonances. Extensive experiments have demonstrated that spectroscopic contrast in PiFM is mediated by opto-mechanical damping of the cantilever oscillation as the optical wavelength is scanned through optical resonance. To our knowledge, this is the first time opto-mechanical damping has been observed in the AFM. We hypothesize that this damping force is a consequence of the dissipative interaction between the sample and the vibrating tip; the modulated light source in PiFM modulates the effective damping constant of the 2nd eigenmode of the cantilever which in turn generate side-band signals producing the PiFM signal at the 1st eigenmode. A series of experiments have eliminated other mechanisms of contrast. By tracking the frequency shift of the PiFM signal at the 1st cantilever eigenmode as the excitation wavenumber is tuned through a mid-infrared absorption band, we showed that the near-field optical interaction is attractive. By using a vibrating piezoelectric crystal to mimic sample thermal expansion in a PiFM operating in mixing mode, we determined that the minimum thermal expansion our system can detect is 30 pm limited by system noise. We have confirmed that van der Waal mediated thermal-expansion forces have negligible effect on PiFM signals by detecting the resonant response of a 4-methylbenzenethiol mono molecular layer deposited on template-stripped gold, where thermal expansion was expected to be < 3 pm, i.e., 10 times lower than our system noise level. Finally, the basic theory for dissipative tip-sample interactions was introduced to model the photoinduced opto-mechanical damping. Theoretical simulations are in excellent agreement with experiment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohammad A. Almajhadi, Syed Mohammad Ashab Uddin, H. Kumar Wickramasinghe. 2019-11-05. Observation of Nanoscale Opto-Mechanical Molecular Damping; Origin of Spectroscopic Contrast in Photo Induced Force Microscopy. https://doi.org/10.1038/s41467-020-19067-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det