A Generalizable Method for Automated Quality Control of Functional Neuroimaging Datasets

Abstract

Over the last twenty five years, advances in the collection and analysis of fMRI data have enabled new insights into the brain basis of human health and disease. Individual behavioral variation can now be visualized at a neural level as patterns of connectivity among brain regions. Functional brain imaging is enhancing our understanding of clinical psychiatric disorders by revealing ties between regional and network abnormalities and psychiatric symptoms. Initial success in this arena has recently motivated collection of larger datasets which are needed to leverage fMRI to generate brain-based biomarkers to support development of precision medicines. Despite methodological advances and enhanced computational power, evaluating the quality of fMRI scans remains a critical step in the analytical framework. Before analysis can be performed, expert reviewers visually inspect raw scans and preprocessed derivatives to determine viability of the data. This Quality Control (QC) process is labor intensive, and the inability to automate at large scale has proven to be a limiting factor in clinical neuroscience fMRI research. We present a novel method for automating the QC of fMRI scans. We train machine learning classifiers using features derived from brain MR images to predict the "quality" of those images, based on the ground truth of an expert's opinion. We emphasize the importance of these classifiers' ability to generalize their predictions across data from different studies. To address this, we propose a novel approach entitled "FMRI preprocessing Log mining for Automated, Generalizable Quality Control" (FLAG-QC), in which features derived from mining runtime logs are used to train the classifier. We show that classifiers trained on FLAG-QC features perform much better (AUC=0.79) than previously proposed feature sets (AUC=0.56) when testing their ability to generalize across studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Matthew Kollada, Qingzhu Gao, Monika S Mellem, Tathagata Banerjee, William J Martin. 2019-12-20. A Generalizable Method for Automated Quality Control of Functional Neuroimaging Datasets. https://arxiv.org/abs/1912.10127

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV

Recasting the Destroy Step of Large Neighborhood Search as Dense Segmentation

Large neighborhood search improves an incumbent by releasing selected variables and repairing the resulting subproblem under a time limit. FOVEA casts variable selection as dense semantic segmentation on a fixed $128\times128$ canvas. A small U-Net reads twelve semantic channels and predicts cell scores, which are decoded into a variable set subject to a fixed variable budget. Family-specific layouts connect the search state to the canvas, while one set of network weights serves four problem families. The FP32 network input occupies $786$\,kB across instance sizes. Our analysis bounds constraint coupling for spatially coherent regions, gives a rank certificate for rounds with zero possible improvement, and bounds the coupling advantage attainable on an expander family. On the tested families and hardware, FOVEA trails the strongest graph encoder at $10^{4}$ variables and overtakes it near $1.5\times10^{4}$; the cost model provides an approximate crossover estimate. At larger sizes, where the graph-encoder baselines exceed device memory, FOVEA reduces the primal integral by $12$ to $16\%$ relative to the best runnable baselines. On the expander family, FOVEA performs comparably to random selection, with a coupling advantage close to one.

eess.IV