Simulation dose enhancement in radiotherapy caused by cisplatin

Abstract

This research considers potential dose increase in target due to cisplatin (Pt) concentration and radiation type. Cisplatin concentrations from 0.003 to 120 mM were used. Monte-Carlo simulation of Linear accelerator (Elekta Synergy) and X-ray tube (Xstrahl300) was carried out using Geant4 and PClab. As the first step of this research, we performed simulation of energy spectrum from radiotherapy units (spectrum model). The next step was the modeling of linear accelerator head and X-ray tube, and the distribution of dose in the water phantom (PDD model). At the second stage, dose changes were investigated in the presence of cisplatin in the target (CIS model). The simulation results showed that the dose escalation can be caused by photon-capture therapy (PCT). There is a dose enhancement in the volume where cisplatin is accumulated. Then higher is concentration, then higher is the effect. However, the photon energy increase from 60 to 250 kV and increase of depth of target reduces the effect of PCT due the decrease of the photoelectric effect cross-section. Should be noticed, that the orthovoltage X-rays energy, listed in the table with results shows higher dose enhancement, than the megavoltage photon beam generated from linear acceleration sources. In addition, that the dose enhancement factors (DEF) are higher in linac without flattening filter, than in linac with flattening filter.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A. A. Baulin. 2020-01-14. Simulation dose enhancement in radiotherapy caused by cisplatin. https://doi.org/10.1088/1748-0221%2F15%2F06%2Fc06061

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph