Search arXivSearch

arXiv · 2001.09211

Modal noise mitigation for high-precision spectroscopy using a photonic reformatter

Abstract

Recently, we demonstrated how an astrophotonic light reformatting device, based on a multicore fibre photonic lantern and a three-dimensional waveguide component, can be used to efficiently reformat the point spread function of a telescope to a diffraction-limited psuedo-slit [arXiv:1512.07309]. Here, we demonstrate how such a device can also efficiently mitigate modal noise -- a potential source of instability in high resolution multi-mode fibre-fed spectrographs). To investigate the modal noise performance of the photonic reformatter, we have used it to feed light into a bench-top near-infrared spectrograph (R {\approx} 9,500, λ {\approx} 1550 nm). One approach to quantifying the modal noise involved the use of broadband excitation light and a statistical analysis of how the overall measured spectrum was affected by variations in the input coupling conditions. This approach indicated that the photonic reformatter could reduce modal noise by a factor of six when compared to a multi-mode fibre with a similar number of guided modes. Another approach to quantifying the modal noise involved the use of multiple spectrally narrow lines, and an analysis of how the measured barycentres of these lines were affected by variations in the input coupling. Using this approach, the photonic reformatter was observed to suppress modal noise to the level necessary to obtain spectra with stability close to that observed when using a single mode fibre feed. These results demonstrate the potential of using photonic reformatters to enable efficient multi-mode spectrographs that operate at the diffraction limit and are free of modal noise, with potential applications including radial velocity measurements of M-dwarfs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fraser A. Pike, Aurélien Benoît, David G. MacLachlan, Robert J. Harris, Itandehui Gris Sánchez, David Lee, Tim A. Birks, Robert R. Thomson. 2020-01-24. Modal noise mitigation for high-precision spectroscopy using a photonic reformatter. https://doi.org/10.1093/mnras%2Fstaa1950

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM