Search arXivSearch

arXiv · 2002.00752

Methodology of selective metallic thin film ablation from susceptible polymer substrate using pulsed femtosecond laser

Abstract

Electronic devices are progressively fabricated on flexible substrates allowing new fields of applications. A maskless and very flexible structuring process is offered by ablation using ultra-short pulse laser irradiation. Usually, certain areas of a functional thin film coating are locally removed to yield the needed device structures. Micro laser patterning quality is not only influenced by the beam properties (beam profile, fluence) but also by pulse overlap, scan repetitions and many other factors such as substrate and coating material. This makes process parameter optimization a challenging task. In this paper, we present a systematic approach to efficiently find suitable parameters for laser-induced ablation of thin films on susceptible polymer substrates. As an example, we use a sputtered NiCr coating with a thickness of 100 $nm$ on a polyimide film made by spin coating of PI-2611 precursor (@ 2000 $rpm$ > ca. 8 $μm$, HD microsystems). Irradiation is conducted using a fs-laser with infrared wavelength of 1030 $nm$ and a pulse length of 212 $fs$. The energy per pulse is varied in the range of 0,29 $μJ$ to 4,83 $μJ$, yielding fluence values between 70 $mJ/cm^2$ and 1,11 $J/cm^2$. Ablation threshold fluence for a 100 $nm$ layer of NiCr was found to be $ϕ_{th}$ ($N_P$:1)=0,50 $J/cm^2$ and the incubation factor was evaluated to be $ξ$=0,53. A clear distinction must be made between the material ablation at the surface of a bulk material and the selective removal of a thin film. In the second case effects such as flaking occur in practice and influence the ablation characteristic. We then investigate different varieties of thin film removal including dot-, line- and areal-ablation. The methodology is presented using a practical example, but can be applied to selective ablation of a wide range of thin film systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chresten von der Heide, Maria Grein, Günther Bräuer, Andreas Dietzel. 2020-02-10. Methodology of selective metallic thin film ablation from susceptible polymer substrate using pulsed femtosecond laser. https://doi.org/10.1364/oe.391084

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

RCS angular control with gradient metasurfaces: design and measurement

This letter proposes the design and measurement of a periodic metasurface that achieves anomalous reflection with reduced RCS in a given parasitic direction. A previous study proposed a semi-analytical model to predict the RCS behavior of such a metasurface. However, this first study did not include any experimental exploration to verify the theoretical results. To complete this study, this work presents an experimental validation of the proposed design, with a focus on manufacturing and measurement issues. The synthesis, design specifications, fabrication method and experimental setup are presented and discussed. Measurement results are also examined in detail, highlighting some limitations in metasurfaces RCS measurements. The proposed metasurface effectively achieves the predicted RCS level reduction in the considered parasitic direction. The agreement between simulation and experimental results demonstrates the accuracy of the modelling and the efficiency of the optimisation procedure.

physics.app-ph

Maximum-Power-Transfer Power Coordinates for Fully Coupled Multiport Thévenin Sources

A power-normalized scattering representation is developed at a fixed frequency for a passive linear time-invariant multiport load driven by a fully coupled multiport Thévenin source. The source is obtained by reducing, at the load reference planes, an independent-source network whose suppressed internal impedance is passive, together with an intervening passive matching network. No diagonal-reference, uncoupled-source-channel, reciprocity, or commutation assumption is required. With $R_s=\mathrm{Herm}\{Z_s\}\succ\mathbf{0}$, completing the square in accepted power identifies the available-power current and motivates the coordinates $\mathbf{a}=\frac12R_s^{-1/2}(\mathbf{V}+Z_s\mathbf{I})$, $\mathbf{b}=\frac12R_s^{-1/2}(\mathbf{V}-Z_s^H\mathbf{I})$. They satisfy $\|\mathbf{a}\|_2^2-\|\mathbf{b}\|_2^2=\Re\{\mathbf{I}^H\mathbf{V}\}$ and yield $\mathbf{S}=R_s^{-1/2}(Z_{load}-Z_s^H)(Z_{load}+Z_s)^{-1}R_s^{1/2}$. An exact operator identity establishes passivity--contractivity equivalence and gives excitation-specific, reachable-subspace, and complete conjugate-matching conditions. On the physically reachable incident subspace, singular values characterize the best- and worst-case source-normalized port-reflection TARC, while a restricted Frobenius norm gives the basis-averaged squared TARC. Equal-magnitude phase-only control is formulated separately as a constant-modulus problem, with generator-side constraints mapped through the coupled source network before power normalization. For antenna loads and excitations with $P_{acc}>0$, $P_{rad}/P_{av}=η_{rad}(1-\mathrm{TARC}^2)$, so terminal scattering data alone do not determine radiation efficiency. When $R_s$ is singular, finite available power exists exactly for $\mathbf{E}\in\mathrm{range}(R_s)$, and the construction applies on the positive-resistance support.

physics.app-ph

Bimorph Lithium Niobate Thickness-Shear Overtone Film Bulk Acoustic Resonator

High quality factor ($Q$) and overtone operation enable narrow-linewidth acoustic devices with multiple discrete frequencies in a single cavity. Maintaining both high $Q$ and sufficient electromechanical coupling at higher mode orders remains challenging. Here, we demonstrate a bimorph periodically poled piezoelectric film (P3F) lithium niobate (LN) platform for high-order thickness-shear (TS) overtone excitation. The device comprises a bonded 80-$μ$m-thick single-crystal X-cut LN bimorph with opposite polarizations, patterned top and floating bottom electrodes, and a suspended air cavity. The P3F configuration mitigates charge cancellation from the alternating stress distribution of higher-order TS modes, enabling measurable coupling across a broad sequence of overtones. The thick LN acoustic cavity and increasingly confined high-order mode profiles support low-loss operation. Measured TS overtones extend to 1.75 GHz. At room temperature, representative overtones at 0.77 and 0.89 GHz exhibit 3-dB $Q$ values of 11,338 and 11,917, corresponding to $fQ$ products of $8.74\times10^{12}$ and $1.06\times10^{13}$ Hz, respectively. Cooling from 297 to 12 K systematically enhances $Q$, yielding a peak 3-dB $Q$ of 20,507 at 779 MHz and a maximum $fQ$ product of $1.98\times10^{13}$ Hz at 1.379 GHz. These results establish bimorph P3F LN as a promising platform for high-$Q$, frequency-scalable micro-acoustic resonators in the sub-GHz and low-GHz regimes.

physics.app-ph