We present the general conditions to realize a fourth order exceptional point of degeneracy (EPD) in two uniform (i.e., invariant along z) lossless and gainless coupled transmission lines (CTLs), namely, a degenerate band edge (DBE). Until now the DBE has been shown only in periodic structures. In contrast, the CTLs considered here are uniform and subdivided into four cases where the two TLs support combinations of forward propagation, backward propagation and evanescent modes (when neglecting the mutual coupling). We demonstrate for the first time that a DBE is supported in uniform CTLs when there is proper coupling between: (i) propagating modes and evanescent modes, (ii) forward and backward propagating modes, or (iii) four evanescent modes (two in each direction). We also show that the loaded quality factor of uniform CTLs exhibiting a fourth order EPD at k=0 is robust to series losses due to the fact that the degenerate modes do not advance in phase. We also provide a microstrip possible implementation of a uniform CTL exhibiting a DBE using periodic series capacitors with very sub-wavelength unit-cell length. Finally, we show an experimental verification of the existence DBE for a microstrip implementation of a CTL supporting coupled propagating and evanescent modes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tarek Mealy, Filippo Capolino. 2020-03-09. General Conditions to Realize Exceptional Points of Degeneracy in Two Uniform Coupled Transmission Lines. https://doi.org/10.1109/tmtt.2020.2999498

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph