Search arXivSearch

arXiv · 2003.06011

Performance limits of adaptive-optics/high-contrast imagers with pyramid wave-front sensors

Abstract

Advanced AO systems will likely utilise Pyramid wave-front sensors (PWFS) over the traditional Shack-Hartmann sensor in the quest for increased sensitivity, peak performance and ultimate contrast. Here, we wish to bring knowledge and quantify the PWFS theoretical limits as a means to highlight its properties and use cases. We explore forward models for the PWFS in the spatial-frequency domain for they prove quite useful since a) they emanate directly from physical-optics (Fourier) diffraction theory; b) provide a straightforward path to meaningful error breakdowns, c) allow for reconstruction algorithms with $O (n\,log(n))$ complexity for large-scale systems and d) tie in seamlessly with decoupled (distributed) optimal predictive dynamic control for performance and contrast optimisation. All these aspects are dealt with here. We focus on recent analytical PWFS developments and demonstrate the performance using both analytic and end-to-end simulations. We anchor our estimates with observed on-sky contrast on existing systems and then show very good agreement between analytical and Monte-Carlo estimates for the PWFS. For a potential upgrade of existing high-contrast imagers on 10\,m-class telescopes with visible or near-infrared PWFS, we show under median conditions at Paranal a contrast improvement (limited by chromatic and scintillation effects) of 2x-5x by replacing the wave-front sensor alone at large separations close to the AO control radius where aliasing dominates, and factors in excess of 10x by coupling distributed control with the PWFS over most of the AO control region, from small separations starting with the Inner Working Angle of typically 1-2 $λ/D$ to the AO correction edge (here 20 $λ/D$).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Carlos M. Correia, Olivier Fauvarque, Charlotte Z. Bond, Vincent Chambouleyron, Jean-Francois Sauvage, Thierry Fusco. 2020-03-12. Performance limits of adaptive-optics/high-contrast imagers with pyramid wave-front sensors. https://doi.org/10.1093/mnras%2Fstaa843

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM