Search arXivSearch

arXiv · 2003.11092

Process Quality Control Strategy for the Phase-2 Upgrade of the CMS Outer Tracker and High Granularity Calorimeter

Abstract

Between 2025 and 2027, some essential components of the CMS (Compact Muon Solenoid) detector - most notably the tracker and the calorimeter endcap - will be upgraded to prepare for HL-LHC (High Luminosity Large Hadron Collider) conditions. The upgraded CMS Outer Tracker and parts of the new CMS High Granularity Calorimeter (HGCAL) will encompass over $50{,}000$ new silicon sensors covering a total area of about $800\,\text{m}^{2}$. The sensor series production requires a dedicated strategy to monitor the quality and stability of the production process. The strategy is based on a test structure set that provides quick and easy access to critical process parameters. These include parameters not directly accessible on the sensors (e.g. oxide charge concentration and interface trap density) and parameters requiring potentially destructive measurements (e.g. dielectric strength). The set is implemented at least twice on each production wafer. It is divided into test structures for initial evaluation of the most relevant process parameters and structures for in-depth analysis. All structures can be contacted using a 20-needle probe card and an automated positioning stage. With this system, the initial analysis of one wafer is possible in about 30 minutes. In this paper, the CMS collaboration presents the quality assurance plan for the Phase-2 Upgrade with a focus on process quality control. We cover sensor process specifics, the layout of the test structure set that will be implemented in the production runs for the CMS Outer Tracker and HGCAL, and measurement results illustrating the functionality of the included test structures.

Explore related subjects

Keep this discovery

BibTeXRIS

Viktoria Hinger. 2020-03-24. Process Quality Control Strategy for the Phase-2 Upgrade of the CMS Outer Tracker and High Granularity Calorimeter. https://arxiv.org/abs/2003.11092

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det