Search arXivSearch

arXiv · 2004.00851

Versatile systems for characterization of large-area silicon pad sensors for highly-granular calorimetry

Abstract

High-granularity calorimeters utilizing silicon pad sensors as main active material are being designed for the CMS endcap calorimeter upgrade and have been proposed for the electromagnetic calorimeters at CLIC, ILC and FCC-ee. The silicon sensors in such experiments are foreseen to cover a very large area of O(1000 $\mathrm{m^2}$). They are typically produced from 6- or 8-inch wafers and consist of a few hundred smaller cells, each with an area of O(0.1 to 1.1 $\mathrm{cm^2}$). Currently the CMS endcap calorimeter upgrade is in a prototyping phase with the aim of choosing the final sensor design. Flexible systems are needed for quick sensor characterization as close as possible to operating conditions, for testing different prototypes and for quality control during mass production. The ARRAY system consists of an active switching matrix PCB with 512 input channels and a passive probe card specific for each sensor layout prototype. The probe card makes contact with each individual pad through spring-loaded pins. ARRAY is designed to measure the leakage current and capacitance per-cell for different bias voltages, keeping the entire sensor area under bias. The Hexaboard probe card follows a similar principle: readout electronics foreseen to be used in the final CMS detector are mounted on a PCB that makes contact with the sensor through spring-loaded pins. It is used to perform noise and charge collection efficiency measurements with irradiated sensors without the need for module assembly. We present the design of the ARRAY and Hexaboard systems as well as measurements performed on different CMS prototype silicon sensors. We also compare the results with alternative multi-needle setups.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pedro Dias de Almeida. 2020-04-02. Versatile systems for characterization of large-area silicon pad sensors for highly-granular calorimetry. https://doi.org/10.1088/1748-0221%2F15%2F06%2Fc06050

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det