Search arXivSearch

arXiv · 2004.01715

Newtonian gravitational constant measurement. All atomic variables become extreme when using a source mass consisting of 3 or more parts

Abstract

Atomic interferometry methods used to measure the Newtonian gravitational constant. To improve the accuracy, one should measure the phase of an atomic interferometer at extreme values of atomic vertical velocities and coordinates. Owing to symmetry, the horizontal components of atomic velocities and coordinates are also extreme. We propose using a source mass consisting of 3 or more parts, since only in this case one can find such an arrangement of parts that all atomic variables become extreme. Nonlinear dependences of the phase on the uncertainties of atomic positions and velocities near those extreme values required us to modify the expression for the phase relative standard deviation (RSD). Moreover, taking into account nonlinear terms in the phase dependence on the atomic coordinates and velocities leads to a phase shift. In the last experiment to measure the Newtonian gravitational constant by atomic interferometry, this shift was not included. We took the shift into account, got a value of 199ppm for it, and this leads to a decrease in the value of the Newton constant by 0.02%. In addition, we showed that at equal sizes of the atomic cloud in the vertical and horizontal directions, as well as at equal atomic vertical and transverse temperatures, systematic errors due to the finite size and temperature of the cloud disappear. The calculation also showed that when using the 13-ton source mass proposed recently, the measurement accuracy can reach 17ppm for a source mass consisting of 4 quarters. We assumed that the source mass consisting of a set of cylinders is used for measurements. We have obtained a new analytical expression for the gravitational field of a homogeneous cylinder.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B. Dubetsky. 2021-02-09. Newtonian gravitational constant measurement. All atomic variables become extreme when using a source mass consisting of 3 or more parts. https://doi.org/10.1088/1681-7575%2Fabc92e

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

$LS/LSJ$ Hybrid Coupling Framework for Auger Angular Distributions of Experimentally Unresolved Multiplets with Isolated Fine-Structure

We present a hybrid $LS/LSJ$ coupling framework for treating state multiplets in the regime $ΔE_\text{int}\sim\hbar/τ_\text{int} \ggΔE_\text{FS}\ggΓ$, where $τ_\text{int}$ is the collision interaction time, $ΔE_\text{FS}$ the fine-structure splitting, and $Γ$ the natural width. In this regime, the collision interaction is fast compared with fine-structure evolution, whereas the individual $J$ levels are well isolated on the scale of their natural widths. The produced multiplet's alignment is therefore described in $LS$ coupling and then projected onto the individual fine-structure $J$ levels before their subsequent decay, described by $LSJ$ coupling. Applied to the multi-open-shell $1s2s2p\,^4\!P_J$ manifold, which closely satisfies these conditions, the hybrid treatment reveals strong suppression and inversion of the Auger angular-distribution anisotropy relative to the traditional pure-$LS$ treatment. It substantially improves agreement with absolute experimental data while using the same $LS$ production cross sections. This hybrid $LS/LSJ$ framework thus provides the appropriate treatment of state multiplets with isolated fine-structure levels, as it retains the $J$-dependent decay dynamics missing from the traditional pure-$LS$ treatment.

physics.atom-ph

A Protocol for Shielding-Enhanced Loading of Single Polar Molecules into Optical Tweezers

We propose the high-fidelity preparation of single bosonic molecules in optical tweezers starting from small tweezer-trapped molecular ensembles. Our scheme combines a static electric field and a microwave field to generate strong, tunable, anisotropic interactions that shield the molecules against two-body collisional loss. We show that this shielding eliminates all long-range bound states, preventing three-body recombination. This elimination persists for all microwave ellipticities, including the experimentally practical limit of linear polarization. Application of an additional electric field gradient can be used to induce controlled spilling of strongly interacting molecules out of the trap until one remains. With realistic experimental parameters, we estimate that single tweezer-trapped NaCs molecules can be isolated from a pair with fidelities exceeding 99\%, and $> 95\%$ per site across an array. These results establish collisional shielding with electric fields as an effective tool for preparing highly-filled tweezer arrays of polar molecules.

physics.atom-ph

Vector Measurements Using Integrated Radio Frequency Atomic Magnetometers

We demonstrate reconstruction of three-dimensional radio-frequency (RF) magnetic-field vectors using a pair of integrated RF atomic magnetometers operated with orthogonal bias-field orientations. A theoretical and experimental analysis identifies a phase-ambiguity dead band that limits reconstruction when the two sensor responses become nearly identical. Measurements performed in an unshielded laboratory environment demonstrate accurate reconstruction of RF magnetic-field orientations and validate the predicted dependence of reconstruction accuracy on signal imbalance. These results establish integrated RF atomic magnetometers as a compact and sensitive platform for directional RF magnetic-field sensing, particularly at low frequencies, and provide a foundation for portable source-localization and field-mapping applications.

physics.atom-ph