In this paper, we present the design and the analysis of an electrochemical circuit for measuring the concentrations of therapeutic drugs using structure-switching aptamers. Aptamers are single-stranded nucleic acids, whose sequence is selected to exhibit high affinity and specificity toward a molecular target, and change its conformation upon binding. This property, when coupled with a redox reporter and electrochemical detection, enables reagent-free biosensing with a sub-minute temporal resolution for in vivo therapeutic drug monitoring. Specifically, we design a chronoamperometry-based electrochemical circuit that measures the direct changes in the electron transfer (ET) kinetics of a methylene blue reporter conjugated at the distal-end of the aptamer. To overcome the high-frequency noise amplification issue when interfacing with a large-size (> 0.25 mm2) implantable electrode, we present a sample-and-hold (S/H) circuit technique in which the desired electrode potentials are held onto noiseless capacitors during the recording of the redox currents. This allows disconnecting the feedback amplifiers to avoid its noise injection while reducing the total power consumption. A prototype circuit implemented in 65-nm CMOS demonstrates a cell-capacitance-insensitive input-referred noise (IRN) current of 15.2 pArms at a 2.5-kHz filtering bandwidth. Tested in human whole blood samples, changes in the ET kinetics from the redox-labeled aminoglycoside aptamers at different kanamycin concentrations are measured from the recorded current waveforms. By employing principal component analysis (PCA) to compensate for the sampling errors, a detection limit (SNR = 1) of 3.1 uM under 1-sec acquisition is achieved at 0.22-mW power consumption.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jun-Chau Chien, Sam W. Baker, H. Tom Soh, Amin Arbabian. 2020-05-07. Design and Analysis of a Sample-and-Hold CMOS Electrochemical Sensor for Aptamer-based Therapeutic Drug Monitoring. https://arxiv.org/abs/2005.03479

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP