Search arXivSearch

arXiv · 2005.06264

Investigation and improvements of the mechanical structure of Cylindrical GEMs for the BESIII experiment

Abstract

Gas Electron Multipliers (GEMs) can be produced in large foils and molded in different shapes. The possibility to create cylindrical layers has opened the opportunity to use such detector as internal tracker at collider experiments. One crucial item is to have low material budget in the active area, so the supporting structure of anode and cathode must be light. KLOE2 collaboration has built the first Cylindrical GEM detector with honeycomb material with carbon fiber skins produced at high temperature. BESIII is developing an innovative CGEM detector with charge and time readout. Among several innovative features, the mechanical structure was designed to be a sandwich of Rohacell and Kapton, a PMI foam. After the transportation of a first production of the detectors from the construction site in Italy to the Institute of High Energy Physics in Beijing, some malfunctions have been observed in some of them, compatible with GEMs deformation inside the detector. We have performed a detailed study by means of an industrial CT scan available in IHEP laboratory and autopsy to the damaged detectors. In this talk, we will review the construction process, the shipment, the findings of the investigation. A new supporting structure of carbon fiber and honeycomb, assembled at room temperature, has been designed and developed. The thickness of the carbon fiber is small enough to keep the material budget of a single detector layer below 0.5$\%$ of a radiation length, while the mechanical robustness results beyond the purpose of a detector for HEP. A first detector with such a mechanical structure has been built and shipped to IHEP, preliminary results from operation (e.g. current stability, discharges, temperature and humidity correlation) of the detectors will be also presented in this talk.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ilaria Balossino. 2020-05-25. Investigation and improvements of the mechanical structure of Cylindrical GEMs for the BESIII experiment. https://doi.org/10.1088/1748-0221%2F15%2F08%2Fc08013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det