Search arXivSearch

arXiv · 2007.07230

Cross-Domain Medical Image Translation by Shared Latent Gaussian Mixture Model

Abstract

Current deep learning based segmentation models often generalize poorly between domains due to insufficient training data. In real-world clinical applications, cross-domain image analysis tools are in high demand since medical images from different domains are often needed to achieve a precise diagnosis. An important example in radiology is generalizing from non-contrast CT to contrast enhanced CTs. Contrast enhanced CT scans at different phases are used to enhance certain pathologies or organs. Many existing cross-domain image-to-image translation models have been shown to improve cross-domain segmentation of large organs. However, such models lack the ability to preserve fine structures during the translation process, which is significant for many clinical applications, such as segmenting small calcified plaques in the aorta and pelvic arteries. In order to preserve fine structures during medical image translation, we propose a patch-based model using shared latent variables from a Gaussian mixture model. We compare our image translation framework to several state-of-the-art methods on cross-domain image translation and show our model does a better job preserving fine structures. The superior performance of our model is verified by performing two tasks with the translated images - detection and segmentation of aortic plaques and pancreas segmentation. We expect the utility of our framework will extend to other problems beyond segmentation due to the improved quality of the generated images and enhanced ability to preserve small structures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yingying Zhu, Youbao Tang, Yuxing Tang, Daniel C. Elton, Sungwon Lee, Perry J. Pickhardt, Ronald M. Summers. 2020-07-14. Cross-Domain Medical Image Translation by Shared Latent Gaussian Mixture Model. https://arxiv.org/abs/2007.07230

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

IViT: A Novel Interpretable Visual Transformer for Skin Disease Detection

The clinical diagnosis of skin diseases is susceptible to interference from inter-class similarity of skin lesions, and over-reliance on clinicians'experience easily leads to subjective bias. Although existing deep learning aided diagnosis methods achieve competitive accuracy, they suffer from the black-box opacity of Vision Transformer (ViT) and poor adaptability to medical few-shot scenarios. Moreover, mainstream explainable algorithms generally face the bottleneck of significant accuracy degradation when improving interpretability. This paper proposes an interpretable ViT (IViT) constrained by Quadratic Programming (QP). The introduced pre-trained transfer learning adapts to few-shot feature extraction. A discrete QP feature selection framework is constructed to screen generic and discriminative features consistent with clinical diagnostic logic. A multi-objective loss function is designed to reduce feature redundancy and optimize activation distribution while preserving classification performance. Experimental results on six standard skin disease datasets show that IViT achieves an accuracy of 93.80%, only 0.21% lower than the baseline, with feature redundancy reduced by 29.5%. Its core activation regions are consistent with clinically concerned lesion areas. The proposed model balances accuracy and interpretability, providing a reliable solution for the clinical deployment of few-shot intelligent skin disease diagnosis.

eess.IV

Automated Distinction of Intimal and Medial Intracranial Arterial Calcification from CT Head

Intracranial arterial calcifications (IACs) are a common finding on clinical non-contrast enhanced head CT scans and are associated with neurovascular disease. Calcifications can occur in the intimal or medial layer of the arterial wall, subtypes that differ in aetiology and may have distinct clinical relevance. These subtypes can be visually distinguished by radiologists based on the shape of the calcifications. We investigate three automated approaches for subtype classification of IAC from head CT-derived segmentation masks: (1) an automated adaptation of the established radiological visual score, (2) a sphericity-based method, and (3) a method based on shape embeddings extracted by a medical shape foundation model. All approaches use the same lightweight classification pipeline on top of the features they compute and are evaluated using 5-fold cross-validation. The three methods achieved comparable performance, with the embedding-based approach yielding the best overall results with a weighted F1 (mean $\pm$ SD) of up to 71.5 $\pm$ 3.7 for a single artery and 59.8 $\pm$ 1.7 for the joint artery classification. Performance was largely preserved when using automated instead of manual IAC segmentation masks, and we found the difference in weighted F1 not significant. Our results show that fully automated IAC subtype quantification from head CT is feasible and remains robust to the use of manual and automated IAC segmentation masks. Code at https://github.com/bjin96/iac-subtyping.

eess.IV

Recasting the Destroy Step of Large Neighborhood Search as Dense Segmentation

Large neighborhood search improves an incumbent by releasing selected variables and repairing the resulting subproblem under a time limit. FOVEA casts variable selection as dense semantic segmentation on a fixed $128\times128$ canvas. A small U-Net reads twelve semantic channels and predicts cell scores, which are decoded into a variable set subject to a fixed variable budget. Family-specific layouts connect the search state to the canvas, while one set of network weights serves four problem families. The FP32 network input occupies $786$\,kB across instance sizes. Our analysis bounds constraint coupling for spatially coherent regions, gives a rank certificate for rounds with zero possible improvement, and bounds the coupling advantage attainable on an expander family. On the tested families and hardware, FOVEA trails the strongest graph encoder at $10^{4}$ variables and overtakes it near $1.5\times10^{4}$; the cost model provides an approximate crossover estimate. At larger sizes, where the graph-encoder baselines exceed device memory, FOVEA reduces the primal integral by $12$ to $16\%$ relative to the best runnable baselines. On the expander family, FOVEA performs comparably to random selection, with a coupling advantage close to one.

eess.IV