Delineation of cancerous regions in gigapixel whole slide images (WSIs) is a crucial diagnostic procedure in digital pathology. This process is time-consuming because of the large search space in the gigapixel WSIs, causing chances of omission and misinterpretation at indistinct tumor lesions. To tackle this, the development of an automated cancerous region segmentation method is imperative. We frame this issue as a modeling problem with partial label WSIs, where some cancerous regions may be misclassified as benign and vice versa, producing patches with noisy labels. To learn from these patches, we propose Self-similarity Student, combining teacher-student model paradigm with similarity learning. Specifically, for each patch, we first sample its similar and dissimilar patches according to spatial distance. A teacher-student model is then introduced, featuring the exponential moving average on both student model weights and teacher predictions ensemble. While our student model takes patches, teacher model takes all their corresponding similar and dissimilar patches for learning robust representation against noisy label patches. Following this similarity learning, our similarity ensemble merges similar patches' ensembled predictions as the pseudo-label of a given patch to counteract its noisy label. On the CAMELYON16 dataset, our method substantially outperforms state-of-the-art noise-aware learning methods by 5$\%$ and the supervised-trained baseline by 10$\%$ in various degrees of noise. Moreover, our method is superior to the baseline on our TVGH TURP dataset with 2$\%$ improvement, demonstrating the generalizability to more clinical histopathology segmentation tasks.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hsien-Tzu Cheng, Chun-Fu Yeh, Po-Chen Kuo, Andy Wei, Keng-Chi Liu, Mong-Chi Ko, Kuan-Hua Chao, Yu-Ching Peng, Tyng-Luh Liu. 2020-07-19. Self-similarity Student for Partial Label Histopathology Image Segmentation. https://arxiv.org/abs/2007.09610

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Hyperspectral Image Restoration and Super-resolution with Physics-Aware Deep Learning for Biomedical Applications

Hyperspectral imaging is a powerful bioimaging tool which can uncover novel insights, thanks to its sensitivity to the intrinsic properties of materials. However, this enhanced contrast comes at the cost of system complexity, constrained by an inherent trade-off between spatial, spectral, and temporal resolution. To overcome this limitation, we present a self-supervised deep learning-based approach that restores and enhances pixel resolution post-acquisition without requiring external training data beyond the images to be restored. Fine-tuned using metrics aligned with the imaging model, our physics-aware method achieves a 16$\times$ pixel super-resolution enhancement and a 12$\times$ imaging speedup without the need of additional training data for transfer learning. Applied to both synthetic and experimental data from five different sample types, including healthy and diseased tissues, we demonstrate that the model preserves biological integrity, as we did not detect systematic loss of biological features or biologically consequential hallucinations in tested datasets. We also concretely demonstrate the model's ability to reveal disease-associated metabolic changes that would otherwise remain undetectable. Furthermore, we provide physical insights into the model's inner workings, paving the way for future refinements that could potentially reveal novel high resolution features in an explainable manner. All methods are available as open-source software on GitHub.

eess.IV

OASIS: Online Adaptive Video Compression via Closed-loop Feedback Control

Computer vision systems are a key building block in an autonomous vehicle, responsible for a range of perception tasks. However, they incur massive data transmission over long communication links from multiple cameras, creating a critical bandwidth and energy bottleneck. Although conventional codecs such as H.264 can reduce data rates, they are ill-suited for real-time vision systems due to high processing latency and energy consumption, as well as their reliance on static user-defined compression settings. In light of these challenges, we propose OASIS, an adaptive video compression framework that integrates lightweight in-sensor compression with task-aware compression ratio control. Based on the real-time task performance, it dynamically updates the optimal compression ratio. Experimental results demonstrate that OASIS generalizes across multiple vision tasks, achieving on average a 6x data compression, 5.8x reduction in link power consumption, and 2.5x reduction in link latency, with at most 1.5% performance degradation.

eess.IV

Echo-E$^3$Net: Efficient Endocardial Spatio-Temporal Network for Ejection Fraction Estimation

Left ventricular ejection fraction (LVEF) is a primary marker of cardiac function. However, routine estimation from endocardial measurements requires manual delineation at end-diastole (ED) and end-systole (ES), a process that is time-consuming and subject to inter-observer variability. Reliable automation is especially valuable for point-of-care ultrasound (POCUS), where computational resources are limited and acquisition quality varies. We propose Echo-E$^3$Net, an anatomy-guided spatio-temporal network that explicitly embeds cardiac anatomy into LVEF prediction. A dual-phase Endocardial Border Detector (E$^2$CBD) uses phase-specific cross-attention to localize ED/ES endocardial landmarks and produce phase-aware landmark embeddings, while an Endocardial Feature Aggregator (E$^2$FA) fuses these embeddings with global statistical descriptors of deep feature maps to refine EF regression. Training is guided by a lightweight geometric loss that uses ED and ES endocardial landmarks to regularize EF prediction. On EchoNet-Dynamic and a PSAX subset of EchoNet-Pediatric, Echo-E$^3$Net attains competitive performance using only 1.55M parameters and 8.05 GFLOPs, an order-of-magnitude compute reduction versus recent baselines, supporting real-time deployment. Our code is publicly available at https://github.com/moeinheidari7829/Echo-E3Net.

eess.IV