Search arXivSearch

arXiv · 2007.11371

Data Processing Software for Chandrayaan-2 Solar X-ray Monitor

Abstract

Solar X-ray Monitor (XSM) instrument of India's Chandrayaan-2 lunar mission carries out broadband spectroscopy of the Sun in soft X-rays. XSM, with its unique features such as low background, high time cadence, and high spectral resolution, provides the opportunity to characterize transient and quiescent X-ray emission from the Sun even during low activity periods. It records the X-ray spectrum at one-second cadence, and the data recorded on-board are downloaded at regular intervals along with that of other payloads. During ground pre-processing, the XSM data is segregated, and the level-0 data is made available for higher levels of processing at the Payload Operations Center (POC). XSM Data Analysis Software (XSMDAS) is developed to carry out the processing of the level-0 data to higher levels and to generate calibrated light curves and spectra for user-defined binning parameters such that it is suitable for further scientific analysis. A front-end for the XSMDAS named XSM Quick Look Display (XSMQLD) is also developed to facilitate a first look at the data without applying calibration. XSM Data Management-Monitoring System (XSMDMS) is designed to carry out automated data processing at the POC and to maintain an SQLite database with relevant information on the data sets and an internal web application for monitoring data quality and instrument health. All XSM raw and calibrated data products are in FITS format, organized into day-wise files, and the data archive follows Planetary Data System-4 (PDS4) standards. The XSM data will be made available after a lock-in period along with the XSM Data Analysis Software from ISRO Science Data Archive (ISDA) at Indian Space Science Data Center(ISSDC). Here we discuss the design and implementation of all components of the software for the XSM data processing and the contents of the XSM data archive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N. P. S. Mithun, Santosh V. Vadawale, Arpit R. Patel, M. Shanmugam, D. Chakrabarty, Partha Konar, Tejas N. Sarvaiya, Girish D. Padia, Aveek Sarkar, Prashant Kumar, Prashant Jangid, Aaditya Sarda, Manan S. Shah, Anil Bhardwaj. 2020-07-22. Data Processing Software for Chandrayaan-2 Solar X-ray Monitor. https://doi.org/10.1016/j.ascom.2021.100449

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM