Search arXivSearch

arXiv · 2008.00776

An ultrasonic measurement of stress in steel without calibration: the angled shear wave identity

Abstract

Measuring stress levels in loaded structures is crucial to assess and monitor their health, and to predict the length of their remaining structural life. However, measuring stress non-destructively has proved quite challenging. Many ultrasonic methods are able to accurately predict in-plane stresses in a controlled laboratory environment, but struggle to be robust outside, in a real world setting. That is because they rely either on knowing beforehand the material constants (which are difficult to acquire) or they require significant calibration for each specimen. Here we present a simple ultrasonic method to evaluate the in-plane stress in situ directly, without knowing any material constants. This method only requires measuring the speed of two angled shear waves. It is based on a formula which is exact for incompressible solids, such as soft gels or tissues, and is approximately true for compressible "hard" solids, such as steel and other metals. We validate the formula against virtual experiments using Finite Element simulations, and find it displays excellent accuracy, with a small error of the order of 1%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Guo-Yang Li, Artur Lewis Gower, Michel Destrade. 2020-08-03. An ultrasonic measurement of stress in steel without calibration: the angled shear wave identity. https://doi.org/10.1121/10.0002959

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Harmonic Vector Fields and Betti Numbers in Bounded Three-Dimensional Electromagnetic Domains

The topology of a bounded three-dimensional domain can strongly affect electromagnetic fields. In a topologically complex domain, a curl-free field may not have a globally single-valued scalar potential and a divergence-free field may also fail to have a global vector potential. These topological effects lead naturally to harmonic vector fields in the Helmholtz decomposition. This paper gives a geometric and constructive study of such fields using vector analysis, circulation integrals, cutting surfaces, scalar Laplace problems, Stokes' theorem, and Green's identity. The first Betti number is interpreted through independent handle-type circulations, whereas the second Betti number counts enclosed voids. Direct proofs are given for the dimensions of the Neumann and Dirichlet harmonic-field spaces. The analysis is also extended to anisotropic lossless media. The results provide a simple topological interpretation of harmonic fields and physical DC modes in bounded electromagnetic resonators.

physics.class-ph

Impact of Phase Unwrapping on Multitarget Acoustic Lenses for Transcranial Holography

Acoustic lenses have been introduced recently to compensate for the phase distortions induced by the propagation across a human skull for ultrasonic deep-brain stimulation in humans. In this study, we present bifocal lenses that compensate for human skull aberrations and allow simultaneous targeting of multiple structures deep in the brain. We investigated the impact of phase unwrapping in the design of the lenses and how this process improves the distribution of pressure produced in N=5 human skulls for two different spatial arrangements of the targets. The results show that unwrapping the phase computed during the design increases the fidelity of the pressure field generated across the human skulls. The spatial precision is on average improved by 73%, and out of target energy deposition is on average reduced by 58%. The results presented in this study highlight the importance of phase unwrapping to optimize the safety and efficacy of future transcranial ultrasound stimulations targeting multiple regions.

physics.class-ph

Contact mechanics and friction of soft materials: an apparatus combining multi-axes dynamical actuation/measurement and in situ/in operando visualisation

The mechanics and friction of contact interfaces involving soft materials like gel, rubber or human skin are of both fundamental and applied interest. Recent insights have been made into this field thanks to in situ observations of the contact interface. However, current soft-material-oriented tribometers enable only few degrees of freedom for the actuation of the contact, far from covering the richness of the loading conditions relevant to real tribological contacts. Here, we introduce an apparatus dedicated to the study of the contact mechanics and friction of soft materials which, in addition to in situ / in operando optical monitoring of the interface, enables simultaneous actuation along five degrees of freedom: three translations and two rotations. While all three translations feature large velocity/large stroke motion, the one responsible for normal contact loading can also apply high frequency/small amplitude vibrations. The contact's dynamical response is monitored using both a 6-axes force/torque sensor and a 6-axes displacement/rotation sensor. We first describe the structure of the apparatus, its implementation, alignment, calibration and resolutions. We then illustrate its capabilities through a series of experiments on elastomer contacts. Our apparatus will be useful to investigate the mechanics of a wide range of soft interfaces submitted to rich, tribology-relevant kinematic or dynamic stimuli.

physics.class-ph