Search arXivSearch

arXiv · 2009.01818

Should a small robot have a small personal space? Investigating personal spatial zones and proxemic behavior in human-robot interaction

Abstract

This paper presents the first study in a series of proxemics experiments concerned with the role of personal spatial zones in human-robot interaction. In the study 40 participants approached a NAO robot positioned approximately at participants' eye level and entered different social zones around the robot (personal and intimate space). When the robot perceived the approaching person entering its personal space, it started gazing at the participant, and upon the intrusion of its intimate space it leaned back. Our research questions were: (1) given the small size of the robot (58 cm tall), will people expect its social zones to shrink by its size? (2) Will the robot behaviors be interpreted as appropriate social behaviors? We found that the average approach distance of the participants was 48 cm, which represents the inner limit of the human-size personal zone (45-120 cm), but is outside of the personal zone scaled to robot size (16-42 cm). This suggests that most participants did not (fully) scale down the extent of these zones to the robot size. We also found that the leaning back behavior of the robot was correctly interpreted by most participants as the robot's reaction to the intrusion of its personal space; however, our implementation of the behavior was often perceived as "unfriendly". We will discuss this and other limitations of the study in detail. Additionally we found positive correlations between participants' personality traits, Godspeed Questionnaire subscales, and the average approach distance. The technical contribution of this work is the real-time perception of 25 keypoints on the human body using a single compact RGB-D camera and the use of these points for accurate interpersonal distance estimation and as gazing targets for the robot.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hagen Lehmann, Adam Rojik, Matej Hoffmann. 2020-09-03. Should a small robot have a small personal space? Investigating personal spatial zones and proxemic behavior in human-robot interaction. https://arxiv.org/abs/2009.01818

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TrialCompass: Visual Analytics for Enhancing the Eligibility Criteria Design of Clinical Trials

Eligibility criteria play a critical role in clinical trials by determining the target patient population, which significantly influences the outcomes of medical interventions. However, current approaches for designing eligibility criteria have limitations to support interactive exploration of the large space of eligibility criteria. They also ignore incorporating detailed characteristics from the original electronic health record (EHR) data for criteria refinement. To address these limitations, we proposed TrialCompass, a visual analytics system integrating a novel workflow, which can empower clinicians to iteratively explore the vast space of eligibility criteria through knowledge-driven and outcome-driven approaches. TrialCompass supports history-tracking to help clinicians trace the evolution of their adjustments and decisions when exploring various forms of data (i.e., eligibility criteria, outcome metrics, and detailed characteristics of original EHR data) through these two approaches. This feature can help clinicians comprehend the impact of eligibility criteria on outcome metrics and patient characteristics, which facilitates systematic refinement of eligibility criteria. Using a real-world dataset, we demonstrated the effectiveness of TrialCompass in providing insights into designing eligibility criteria for septic shock and sepsis-associated acute kidney injury. We also discussed the research prospects of applying visual analytics to clinical trials.

cs.HC

PRIMMDebug: Teaching Secondary School Students a Reflective Approach to Debugging

Debugging is a challenging and infuriating experience for many secondary school students learning their first text-based programming language. One frequent problem is the lack of reflection in students' debugging strategies, which makes error resolution unlikely and teacher reliance common. Tools that encourage more reflective and teacher-independent debugging may foster more success with fixing errors, but are lacking. This paper presents PRIMMDebug, an approach for teaching the debugging process to secondary school students. PRIMMDebug consists of an online tool that takes students through the steps of a pedagogical process based on PRIMM, a framework for teaching programming. The tool encourages written articulation throughout the debugging process and limits students' ability to run and edit code at certain stages. A classroom study with PRIMMDebug found a general reluctance among students to engage with the reflection it promotes, despite teachers appreciating this emphasis on reflection. We end by suggesting three considerations for future pedagogical debugging research and tooling: balance structure and flexibility, teach shorter debugging heuristics, and use tooling early on in students' programming journey.

cs.HC

Mirror Skin: In Situ Visualization of Robot Touch Intent on Robotic Skin

Effective communication of robot touch intent is essential for safe and predictable physical human-robot interaction. While intent communication has been widely studied, existing approaches lack the spatial specificity and semantic depth necessary to efficiently convey robot touch intent. We present Mirror Skin, a cephalopod inspired concept that mirrors in-situ visual representations of a human's body parts onto the corresponding robot's touch region to communicate who shall initiate touch, where it will occur, and when it is imminent. We informed the design of Mirror Skin through a structured design exploration with experts and demonstrate the real-world feasibility of Mirror Skin with a proof-of-concept prototype. User studies in VR and with the physical prototype showed that Mirror Skin significantly improves accuracy and response times for interpreting touch intent and improves the user experience during physical human-robot interactions.

cs.HC