Fat and fibrosis as confounding cofactors in viscoelastic measurements of the liver

Abstract

Elastography provides significant information on staging of fibrosis in patients with liver disease and may be of some value in assessing steatosis. However, there remain questions as to the role of steatosis and fibrosis as cofactors influencing the viscoelastic measurements of the liver tissues, particularly shear wave speed (SWS) and shear wave attenuation (SWA). In this study, by employing the theory of composite elastic media as well as two independent experimental measurements on fat-in-gelatin phantoms and also finite element simulations, it is consistently shown that fat and fibrosis jointly influence the SWS and SWA measurements. At a constant level of fat, fibrosis stages can influence the SWA by factors of 2-4. Moreover, the rate of increase in SWA with increasing fat is strongly influenced by the stages of fibrosis; softer background cases (low fibrosis stages) have higher rate of SWA increase with fat than those with stiffer moduli (higher fibrosis stages). Meanwhile, SWS results are influenced by the presence of fat, however the degree of variability is more subtle. The results indicate the importance of jointly considering fat and fibrosis as contributors to SWS and SWA measurements in complex liver tissues and in the design and interpretation of clinical trials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sedigheh S. Poul, Kevin J. Parker. 2020-09-15. Fat and fibrosis as confounding cofactors in viscoelastic measurements of the liver. https://arxiv.org/abs/2009.04895

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A 2D autocorrelation-based frequency estimator reflecting spatial tissue distribution to improve Ultrasound H-scan tissue characterization

H-scan is a promising quantitative ultrasound technique that estimates the frequency content of backscattered signals and maps the estimated frequencies onto a red/blue color scale to reflect underlying tissue properties. Although it relies on matched filters tuned to different frequencies, the broad spectral bandwidth of ultrasound produces noisy, granular displays. Here, we introduce an adaptive frequency estimator designed to suppress the noise within homogeneous regions while preserving sharpness across tissue boundaries. The method combines 2D autocorrelation with a matched filter. In the first stage, a matched-filter-based estimation yields an a priori map of the spatial distribution of frequencies. The local heterogeneity of these estimates then defines a 2D weighting function that guides a second estimation stage. Drawing on the concept of Loupas's blood velocity estimator, we apply autocorrelation over a 2D spatial kernel to recover the axial frequency components, employing a weighted summation that accounts for the spatial frequency distribution within the kernel. We benchmarked the proposed estimator against conventional approaches, including the short-time Fourier transform, the H-scan matched filter, and standard autocorrelation, using both Field II simulations and in vivo data from human subjects with hepatic steatosis. In simulation, our adaptive estimator reduced the noisy texture in homogeneous regions while retaining clear boundary delineation, whereas the other estimators could achieve only one of these objectives. Applied to the in vivo human liver, the estimator improved H-scan image quality by lowering noise and enhancing the discrimination of steatotic liver from adjacent gallbladder and skin layers.

physics.med-ph↗

Improving Multi-Delay-ASL through specialized reconstruction

Purpose: Although image reconstruction has received relatively little attention in ASL research to date, it has the potential to address several challenges in ASL. As well as speeding up measurements by increasing undersampling and reducing measurement artifacts, it can improve the signal-to-noise ratio (SNR) of a given data set and the reproducibility of examinations. Methods: This work focuses on extending a dedicated ASL reconstruction approach (ASL-TGV) (Spann et al. (2020)) to multi-delay data and applying it to a high-resolution pCASL test-retest dataset. To show not only improvement in the Perfusion Weighted Images (PWIs), Cerebral Blood Flow and Arterial Transit Time was estimated and the test-retest reliability was estimated using the within subject Coefficient of Variance (wsCV), the Intraclass Correlation Coefficient (ICC) and Root-Mean-Squared-Error (RMSE). Results: The Perfusion-Weighted-Images reconstructed from highly undersampled single-shot data using ASL-TGV are clearly improved compared to a fully-sampled reference from the same data even after denoising, especially for long PLDs and the outermost slices. SNR calculated in grey and white matter ROIs shows an improvement of 62\% and 35\% respectively. The CBF maps produced from the ASL-TGV images have an improved test-retest reliability. Conclusion: ASL-TGV, which is now implemented in the Berkeley Advanced Reconstruction Toolbox (BART), can be used with any type of ASL labeling or data acquisition and any existing image post-processing pipeline and can improve SNR for the PWIs and reproducibility of the CBF maps.

physics.med-ph↗

Fingertip Micro-Motion as a Source of Respiratory Information During Sleep Using Triaxial Accelerometers

Objective: Triaxial accelerometers (TAAs) are widely used in home care medicine. This study investigates whether TAA signals recorded at the fingertip encode respiratory information, particularly instantaneous respiratory rate (IRR) and respiratory effort, during sleep. Method: We propose an antiderivative-based nonlinear transformation to convert TAA signals into a respiratory surrogate, termed TAA-resp. To quantify the embedded respiration-induced oscillation, a modern time-frequency analysis tool is applied to derive an index, referred to as the {\em respiratory motion index} (RMI). The proposed TAA-resp and RMI are validated on two datasets comprising 39 Asians and 10 white or African Americans with full-night recordings from simultaneous polysomnography (PSG) and a fingertip TAA measurement. Criteria for labeling TAA-resp signal quality as good, moderate, or poor are established, and two experts' independent annotations with consensus are obtained. Result: On average, TAA-resp encodes high-quality respiratory information in over 21.25%$\pm$16.11% of full-night recordings, reaching up to 58.33% in some cases. TAA-resp shows stronger correlation with thoracic and abdominal motion than with airflow, indicating predominant capture of respiratory effort. High-quality TAA-resp segments offer an accurate IRR estimate with root mean square error $0.027\pm 0.022$ Hz. RMI is higher for high-quality segments and lower for poor-quality segments, and its distribution aligns with physiology, with higher values during REM, N2, and N3 sleep and in the absence of apnea or hypopnea events. In leave-one-subject-out cross-validation, RMI predicts quality labels with 0.84 sensitivity and 0.88 specificity. Conclusion: Fingertip-mounted TAAs encode meaningful respiratory information intermittently, and our method recycles underutilized respiratory information.

physics.med-ph↗