Search arXivSearch

arXiv · 2010.15450

FPGA Based Real-Time Image Manipulation and Advanced Data Acquisition For 2D-XRAY Detectors

Abstract

Scientific experiments rely on some type of measurements that provides the required data to extract aimed information or conclusions. Data production and analysis are therefore essential components at the heart of any scientific experimental application. Traditionally, efforts on detector development for photon sources have focused on the properties and performance of the detection front-ends. In many cases, the data acquisition chain as well as data processing, are treated as a complementary component of the detector system and added at a late stage of the project. In most of the cases, data processing tasks are entrusted to CPUs; achieving thus the minimum bandwidth requirements and kept hardware relatively simple in term of functionalities. This also minimizes design effort, complexity and implementation cost. This approach is changing in the last years as it does not fit new high-performance detectors; FPGA and GPUs are now used to perform complex image manipulation tasks such as image reconstruction, image rotation, accumulation, filtering, data analysis and many others. This frees up CPUs for simpler tasks. The objective of this paper is to present both the implementation of real time FPGA-based image manipulation techniques, as well as, the performance of the ESRF data acquisition platform called RASHPA, into the back-end board of the SMARTPIX photon-counting detector developed at the ESRF.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wassim Mansour, Rattana Biv, Cyril Ponchut, Raphael Ponsard, Nicolas Janvier, Pablo Fajardo. 2020-10-29. FPGA Based Real-Time Image Manipulation and Advanced Data Acquisition For 2D-XRAY Detectors. https://doi.org/10.1109/tns.2021.3086416

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Kinematic Fitting of electromagnetic calorimeter data - an improved method

Kinematic fitting is widely used in particle physics experiments as a powerful tool to improve experimental resolutions, to suppress background and to provide selection criteria for the identification of specific reactions. Kinematic fitting methods, however, typically assume that the fitted quantities follow Gaussian distributions; an assumption which does not always hold. This is particularly true for energy measurements from electromagnetic calorimeters. This issue can largely be overcome by performing a transformation of the non-Gaussian variables into variables which follow a Gaussian distribution. The new adapted kinematic fitting procedure allows to better account for the non-Gaussian nature of the measured calorimeter energies, at the same time improving the accuracy and robustness of the kinematic fit. This leads to improved pull and confidence-level distributions of the kinematic fit as well as improved invariant mass distributions and signal-to-background ratios in the final event sample.

physics.ins-det

Radiation hardness characterization of SiPM sensors for Low Earth Orbit space missions

This work presents a comprehensive radiation hardness characterization of SiPM devices for space-based applications: FBK NUV-HD-MT and NUV-HD-LowCT (1$\times$1, 3$\times$3, and 6$\times$6~mm$^2$) and Hamamatsu S14160 MPPCs with equivalent active areas. Total Ionizing Dose (TID) tests were performed at the ESA/ESTEC Co-60 facility with a level of dose up to 20~krad in silicon, while displacement damage effects were evaluated using 100~MeV protons with a fluence up to $1.12\times10^{11}$~p/cm$^2$ at the Paul Scherrer Institute. Radiation damage in SiPMs manifests through two main mechanisms: ionizing energy loss and non-ionizing energy loss (NIEL), which increases dark current and dark count rate. In this work, breakdown voltage, dark current, and quenching resistance were systematically measured as functions of accumulated dose and fluence. Gain and dark count rates were indirectly measured from the characterized electrical parameters. Both technologies exhibit remarkable stability of most of the functional parameters across all dose levels, while dark current shows predictable increases significantly more pronounced under proton irradiation due to displacement damage. Based on these results, both FBK and Hamamatsu devices are confirmed suitable for Low Earth Orbit (LEO) mission environment.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det