A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility

Abstract

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

Explore related subjects

Keep this discovery

BibTeXRIS

The CUPID Interest Group, A. Armatol, E. Armengaud, W. Armstrong, C. Augier, F. T. Avignone III, O. Azzolini, I. C. Bandac, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, M. Beretta, L. Bergé, Ch. Bourgeois, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. M. Calvo-Mozota, J. Camilleri, A. Candela, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, A. Cazes, E. Celi, C. Chang, M. Chapellier, A. Charrier, D. Chiesa, M. Clemenza, I. Colantoni, F. Collamati, S. Copello, F. Cova, O. Cremonesi, R. J. Creswick, A. Cruciani, A. D'Addabbo, G. D'Imperio, I. Dafinei, F. A. Danevich, M. de Combarieu, M. De Deo, M. De Jesus, P. de Marcillac, S. Dell'Oro, S. Di Domizio, V. Dompe, A. Drobizhev, L. Dumoulin, G. Fantini, M. Fasoli, M. Faverzani, E. Ferri, F. Ferri, F. Ferroni, E. Figueroa-Feliciano, J. Formaggio, A. Franceschi, C. Fu, S. Fu, B. K. Fujikawa, J. Gascon, A. Giachero, L. Gironi, A. Giuliani, P. Gorla, C. Gotti, P. Gras, M. Gros, E. Guerard, T. D. Gutierrez, K. Han, E. V. Hansen, K. M. Heeger, D. L. Helis, H. Z. Huang, R. G. Huang, A. Ianni, L. Imbert, J. Johnston, A. Juillard, G. Karapetrov, G. Keppel, H. Khalife, V. V. Kobychev, Yu. G. Kolomensky, S. I. Konovalov, Y. Liu, P. Loaiza, L. Ma, M. Madhukuttan. 2020-11-27. A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility. https://doi.org/10.1088/1748-0221/16/02/p02037

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det