Search arXivSearch

arXiv · 2102.00612

Image reconstruction method for dual-isotope positron emission tomography

Abstract

We developed a positron emission tomography (PET) system for multiple-isotope imaging. Our PET system, named multiple-isotope PET (MI-PET), can distinguish between different tracer nuclides using coincidence measurement of prompt gamma-rays, which are emitted after positron emission. In MI-PET imaging with a pure positron emitter and prompt-gamma emitter, because of the imperfectness of prompt gamma-ray detection, an image for a pure positron emitter taken by MI-PET is superposed by a positron-γ emitter. Therefore, in order to make isolated images of the pure positron emitter, we developed image reconstruction methods based on data subtraction specific to MI-PET. We tested two methods, subtraction between reconstructed images and subtraction between sinogram data. In both methods, normalization for position dependence of the prompt γ-ray sensitivity is required in addition to detector sensitivity normalization. For these normalizations, we performed normalization scans using cylindrical phantoms of the positron-gamma emitters Sc-44m and Na-22. A long period measurement using the activity decay of Sc-44m (Half-life 58.6 hours) elucidated that the acquisition ratio between the prompt gamma-rays coincided with PET event and pure PET event changes on the basis of object activities. Therefore, we developed a correction method that involves subtraction parameters dependent on the activities, i.e., the counting rate. From analysis of dual-tracer phantom images, data subtraction in the sinogram data with sensitivity correction gives a higher quality of isolated images for the pure positron emitter than those from image subtractions. Furthermore, from dual-isotope (F-18-FDG and Sc-44m) mouse imaging, we concluded that our developed method can be used for practical imaging of a living organism.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tomonori Fukuchi, Mika Shigeta, Hiromitsu Haba, Daiki Mori, Takuya Yokokita, Yukiko Komori, Seiichi Yamamoto, Yasuyoshi Watanabe. 2021-02-01. Image reconstruction method for dual-isotope positron emission tomography. https://doi.org/10.1088/1748-0221%2F16%2F01%2Fp01035

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph