Search arXivSearch

arXiv · 2102.01763

Optimization of the high-frequency magnetoimpedance response in melt-extracted Co-rich microwires through novel multiple-step Joule heating

Abstract

The optimization of high frequency giant magnetoimpedance (GMI) effect and its magnetic field sensitivity in melt-extracted Co69.25Fe4.25Si13B12.5Nb1 amorphous microwires, through a multi-step Joule annealing (MSA) technique, was systematically studied. The surface morphology, microstructure, surface magnetic property, and high frequency GMI response of the Co-rich microwires were explored using scanning electron microscopy (SEM), magneto-optical Kerr effect (MOKE) magnetometry, transmission electron microscopy (TEM), and impedance analyzer, respectively. An initial dc current (idc) of 20 mA, which was then increased by 20 mA at every time-step (10 min) up to 300 mA, was applied to the microwires. The MSA of 20 mA to 100 mA remarkably improved the GMI ratio and its field sensitivity up to 760% (1.75 time of that of the as-prepared), and 925%/Oe (more than 17.92 times of that of the as-prepared) at an operating frequency of 20 MHz, respectively. Our study indicates that the MSA technique can enhance the microstructures and the surface magnetic domain structures of the Co-rich magnetic microwires, giving rise to the GMI enhancement. This technique is suitable for improving the GMI sensitivity at small magnetic fields, which is highly promising for biomedical sensing and healthcare monitoring.

Explore related subjects

Keep this discovery

BibTeXRIS

O. Thiabgoh, T. Eggers, C. Albrecht, V. O. Jimenez, H. Shen, S. D. Jiang, J. F. Sun, D. S. Lam, V. D. Lam, M. H. Phan. 2021-02-02. Optimization of the high-frequency magnetoimpedance response in melt-extracted Co-rich microwires through novel multiple-step Joule heating. https://arxiv.org/abs/2102.01763

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det