First Application of Large Reactivity Measurement through Rod Drop Based on Three-Dimensional Space-Time Dynamics

Abstract

Reactivity measurement is an essential part of a zero-power physics test, which is critical to reactor design and development. The rod drop experimental technique is used to measure the control rod worth in a zero-power physics test. The conventional rod drop experimental technique is limited by the spatial effect and the difference between the calculated static reactivity and measured dynamic reactivity; thus, the method must be improved. In this study, a modified rod drop experimental technique that constrains the detector neutron flux shape function based on three-dimensional space-time dynamics to reduce the reactivity perturbation and a new method for calculating the detector neutron flux shape function are proposed. Correction factors were determined using Monte Carlo N-Particle transport code and transient analysis code for a pressurized water reactor at the Ulsan National Institute of Science and Technology and Xi'an Jiaotong University, and a large reactivity of over 2000 pcm was measured using the modified technique. This research evaluated the modified technique accuracy, studied the influence of the correction factors on the modification, and investigated the effect of constraining the shape function on the reactivity perturbation reduction caused by the difference between the calculated neutron flux and true value, using the new method to calculate the shape function of the detector neutron flux and avoiding the neutron detector response function (weighting factor) calculation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wencong Wang, Liyuan Huang, Caixue Liu, Han Feng, Jiang Niu, Qidong Dai, Guoen Fu, Linfeng Yang, Mingchang Wu. 2021-02-09. First Application of Large Reactivity Measurement through Rod Drop Based on Three-Dimensional Space-Time Dynamics. https://arxiv.org/abs/2102.12366

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det