Abstract
Brain-computer interface (BCI) systems are usually designed specifically for each subject based on motor imagery. Therefore, the usability of these networks has become a significant challenge. The network has to be designed separately for each user, which is time-consuming for the user. Therefore, this study proposes a method by which the calibration time is significantly reduced while the classification accuracy is increased. In this method, we calibrated the features extracted from the motor imagery task by dividing the features extracted from the resting-state into both open-eye and closed-eye modes and the state in which the subject moves his eyes. The best classification accuracy was obtained using the SVM classifier using the resting-state signal in the open eye, which increased by 3.64% to 74.04%. In this paper, we also investigated the effect of recording time of the resting-state signal and the impact of eye state on the classification accuracy.
Explore related subjects
Keep this discovery
M. Amin. Ghasemi, Sadjaad Ozgoli, Ali. M. NasrAbadi. 2021-03-17. A New Method for Features Normalization in Motor Imagery Few-Shot Learning using Resting-State. https://arxiv.org/abs/2103.09507