Search arXivSearch

arXiv · 2104.01188

Scan Specific Artifact Reduction in K-space (SPARK) Neural Networks Synergize with Physics-based Reconstruction to Accelerate MRI

Abstract

Purpose: To develop a scan-specific model that estimates and corrects k-space errors made when reconstructing accelerated Magnetic Resonance Imaging (MRI) data. Methods: Scan-Specific Artifact Reduction in k-space (SPARK) trains a convolutional-neural-network to estimate and correct k-space errors made by an input reconstruction technique by back-propagating from the mean-squared-error loss between an auto-calibration signal (ACS) and the input technique's reconstructed ACS. First, SPARK is applied to GRAPPA and demonstrates improved robustness over other scan-specific models, such as RAKI and residual-RAKI. Subsequent experiments demonstrate that SPARK synergizes with residual-RAKI to improve reconstruction performance. SPARK also improves reconstruction quality when applied to advanced acquisition and reconstruction techniques like 2D virtual coil (VC-) GRAPPA, 2D LORAKS, 3D GRAPPA without an integrated ACS region, and 2D/3D wave-encoded images. Results: SPARK yields 1.5x - 2x RMSE reduction when applied to GRAPPA and improves robustness to ACS size for various acceleration rates in comparison to other scan-specific techniques. When applied to advanced reconstruction techniques such as residual-RAKI, 2D VC-GRAPPA and LORAKS, SPARK achieves up to 20% RMSE improvement. SPARK with 3D GRAPPA also improves performance by ~2x and perceived image quality without a fully sampled ACS region. Finally, SPARK synergizes with non-cartesian 2D and 3D wave-encoding imaging by reducing RMSE between 20-25% and providing qualitative improvements. Conclusion: SPARK synergizes with physics-based acquisition and reconstruction techniques to improve accelerated MRI by training scan-specific models to estimate and correct reconstruction errors in k-space.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yamin Arefeen, Onur Beker, Jaejin Cho, Heng Yu, Elfar Adalsteinsson, Berkin Bilgic. 2022-04-28. Scan Specific Artifact Reduction in K-space (SPARK) Neural Networks Synergize with Physics-based Reconstruction to Accelerate MRI. https://doi.org/10.1002/mrm.29036

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circulant ADMM-Net for Fast High-resolution DoA Estimation

This paper introduces CADMM-Net and CHADMM-Net, two deep neural networks for direction of arrival estimation within the least-absolute shrinkage and selection operator (LASSO) framework. These two networks are based on a structured deep unfolding of the alternating direction method of multipliers (ADMM) algorithm through the use of circulant as well as Hermitian-circulant matrices. Along with a computational complexity of $\mathcal{O}(N\log(N))$ per layer for the inference, where $N$ is the length of the dictionary $\mathbf{A}$, they additionally exhibit a memory footprint of $N$ and approximately half of $N$ for CADMMNet and CHADMM-Net, respectively, compared with $N^{2}$ for ADMM-Net. Furthermore, these structured networks exhibit a competitive performance against ADMM-Net, LISTA, TLISTA, and THLISTA with respect to the detection rate, the angular root-mean square error, and the normalized mean squared error.

eess.SP

BASIIS: Bistatic Angular Sampling and Interpolation for ISAC Setups

Integrated Sensing and Communications (ISAC) is a defining feature of 6G, extending cellular networks with radar-like sensing at limited additional overhead. In bistatic deployments, sensing requires coordinating the transmitter (TX) and receiver (RX) arrays to scan the Cartesian product of angle of departure and arrival, resulting in a four-dimensional sampling problem in the angular domain. This work establishes a complete angular sampling framework for bistatic ISAC, extending the DFT-based optimal-sampling methodology to the full azimuth and elevation domains of both arrays. We show that the bistatic geometry couples the TX and RX elevation angles, and represent this coupling through the ortho-baseline coarray, a virtual array that captures the joint elevation aperture of the array pair. From the coarray we derive a minimal sampling and interpolation scheme, near-lossless and realizable with any beamforming architecture. Monte Carlo simulations confirm the proposed minimal acquisition essentially equalizes the detection accuracy of dense oversampled imaging while acquiring 3 to 5 times fewer TX-RX direction pairs. This allows having bistatic operations with drastically reduced overhead on the radio resource usage of ISAC systems.

eess.SP

Centroid Angle Estimation of Multiple Scatterers Using Monopulse Radar with Frequency Diversity

The monopulse technique determines the angle of a target by comparing signals from two narrow beams, yielding a precise angular estimate with low complexity. However, it struggles to resolve multiple closely spaced scatterers within the same resolution cell. Existing methods for estimating multiple scatterer angles involve complex signal processing and system modifications. We propose an effective method to estimate the angular centroid of scatterers using the mode of monopulse angle estimates. A semi-analytic expression for the angle estimate distribution is derived, confirming that its mode aligns with the centroid. To enhance estimation accuracy, we employ frequency diversity to reduce sample correlation. Numerical results validate the advantages of the proposed method, demonstrating superior performance over conventional techniques with low complexity.

eess.SP