Search arXivSearch

arXiv · 2105.10322

Characterisation of the PTB ion counter nanodosimeter's target volume and its equivalent size in terms of liquid H2O

Abstract

For the first time a dedicated investigation of the target size of a nanodosimeter device has been carried out in order to investigate to what extent measured ionisation cluster size distributions can serve as benchmark data for modelling approaches, with particular focus on the target size in terms of liquid H2O. To this end, measurements with alpha particles from a 241Am source were carried out using three different target gases, H2O, C3H8 and C4H8O. For each of the three target gases, three different drift-time windows were applied to realise three different target sizes. A method has been developed to determine the dimensions of the simulated nanometric target volume in liquid H2O for cylindrical and spherical shape, as often used in approaches to model radiation effects to DNA. Simulations with nanometric targets of dimensions determined with this method agree very well with the corresponding measurements. Scaling of the spatial distribution of the extraction efficiency for different target gases and drift-time windows, which corresponds to the nanodosimeter's target volume, in terms of liquid H2O using ($ρλ_{ion}$)-ratios has also been investigated and proved to yield an estimate of the target volume in liquid H2O. Thus, it can be concluded that ionisation cluster size distributions measured with a nanodosimeter device are suited as benchmark data for approaches that model radiation induced damage to DNA in nanometric volumes of liquid H2O in simple geometries such as cylinders or spheres, provided that the nanodosimeter's target volume is characterised accordingly. By proper selection of drift-time window length as well as target gas and density a wide range of target volume dimensions in terms of liquid H2O can be realised with the PTB Ion Counter nanodosimeter according to specific requirements of modelling approaches.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gerhard Hilgers, Thomas Braunroth, Hans Rabus. 2021-05-21. Characterisation of the PTB ion counter nanodosimeter's target volume and its equivalent size in terms of liquid H2O. https://doi.org/10.1016/j.radphyschem.2021.109862

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det