Search arXivSearch

arXiv · 2106.05826

High-precision Time-Frequency Signal Simultaneous Transfer System via a WDM-based Fiber Link

Abstract

In this paper, we demonstrate a wavelength division multiplexing (WDM) based system for simultaneously delivering ultrastable optical frequency reference, 10 GHz microwave frequency reference, and one pulse per second (1 PPS) time signal via a 50 km fiber network. For each signal, a unique noise cancellation technique is used to maintain the precision of them. After being compensated, the transfer frequency instability in terms of overlapping Allan deviation (OADEV) for the optical frequency achieves 2E-17/s and scales down to 2E-20/10000 s, which for the 10 GHz microwave reference approaches 4E-15/s and decreases to 1.4E-17/10000 s, and the time uncertainty of the 1 PPS time signal along the system is 2.08 ps. In this scheme, specific channels of WDM are respectively occupied for different signals to avoid the possible crosstalk interference effect between the transmitted reference signals. To estimate the performance of the above scheme, independent of these signals is also demonstrated in this 50 km link, the results are similar to that in the case of simultaneous delivery. This work shows that the WDM-based system is a promising method for building a nationwide time and frequency fiber transfer system with a communication optical network.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zang Qi, Quan Honglei, Zhao Kan, Zhang Xiang, Xue Wenxiang, Chen Faxi, Zhao Wenyu, Liu Tao, Dong Ruifang, Zhang Shougang. 2021-07-08. High-precision Time-Frequency Signal Simultaneous Transfer System via a WDM-based Fiber Link. https://arxiv.org/abs/2106.05826

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det