Search arXivSearch

arXiv · 2107.08284

Design and Fabrication of a Microfluidic System with Nozzle/Diffuser Micropump and Viscosity

Abstract

Micropumps are one of the most important parts of a microfluidic system. In particular, for biomedical applications such as Lab-on-Chip systems, micropumps are used to transport and manipulate test fluids in a controlled manner. In this work, a low-cost, structurally simple, piezoelectrically actuated micropump was simulated and fabricated using poly-dimethylsiloxane (PDMS). The channels in PDMS were fabricated using patterned SU-8 structures. The pump flow rate was measured to be 9.49 uL/min, 14.06 uL/min, 20.87 uL/min for applied voltages of 12 V, 14 V, 16 V respectively. Further, we report finite element analysis (FEA) simulation to confirm the operation of the micropump and compare favorably the experimentally obtained flowrate with the one predicted by simulation. By taking these flow rates as a reference, the chamber pressure was found to be 1.1 to 1.5 kPa from FEA simulations. Viscosity measurement has wide-ranging applications from the oil industry to the pharmaceutical industry. This work provides an elaborate mathematical model and study of measurement of viscosity in real-time using pressure sensors. For a given flowrate, a change in liquid viscosity gives rise to a change in pressure difference across a particular section of the pipe. Hence, by recording the pressure change, viscosity can be calculated dynamically. Mathematical modeling as well as finite element analysis (FEA) modeling has been presented. A set of pressure sensors were placed at a fixed distance from each other to get the real-time pressure change. Knowing the flow rate in the channel, the viscosity has been calculated from the pressure difference. For the finite element analysis, the pressure sensors were placed 60 mm away from each other. A different ratio of the mixture of water and glycerol was used to provide variable viscosity, which led to the variation in pressure-difference values.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sumana Bhattacharjee. 2021-07-17. Design and Fabrication of a Microfluidic System with Nozzle/Diffuser Micropump and Viscosity. https://arxiv.org/abs/2107.08284

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mathematical modeling on peristaltic flow of a Prandtl fluid with effects of slip conditions and inclined magnetic field

The manuscript provides a description of a theoretical analysis of a non-Newtonian Prandtl fluid subject to peristaltic flow through an inclined asymmetric channel. We explore the effect of an inclined magnetic field on the peristaltic flow. This is relevant for applications involving fluid flow in narrow, inclined (tilted) tubes similar to blood vessels or the digestive system. The model also includes thermodynamic aspects such as heat diffusion (the Soret effect) and viscous dissipation resulting from wall-fluid slip conditions, which may help optimize medical devices such as lab-on-a-chip systems and dialysis machines. In this study, the concentration of a generic chemical, temperature, and fluid velocity are taken into account through mass, heat, and momentum balances, respectively. The solution is approximated using numerical techniques suitable for long wavelengths (low frequency) and low Reynolds numbers. The study also discusses trapping phenomena, which are crucial from a clinical point of view. The developed insights can improve the understanding of physiological flows in the gastrointestinal tract and blood vessels. By understanding how the fluid moves and how particles are trapped, these insights may contribute to the design of improved medical pumps and artificial organs. Graphical visualizations are provided for the fluid velocity profile, temperature distribution, and concentration of a generic chemical. Furthermore, the numerical results are validated through comparison with a closed-form solution from a benchmark problem.

physics.flu-dyn

Discovery of a dispersion model at high Peclet numbers

Peclet number characterises the transition from classical Taylor-Aris dispersion to convection-dominated longitudinal solute transport, with the classical model becoming inadequate at extremely high radial Peclet number $Pe_r$. We develop a novel explicit-closure one-dimensional (1-D) effective dispersion model for this high-$Pe_r$ regime by introducing two closure coefficients, $θ_u$ and $θ_d$, whose functional structures are identified using low-frequency transfer-function matching and a modified Kolmogorov-Arnold network (KAN). The resulting model captures the transition from classical Taylor-Aris dispersion at low $Pe_r$ to convection-dominated dispersion at high $Pe_r$. Analysis reveals that, in the high-$Pe_r$ regime, axial transport is redistributed between the effective convection flux and the dispersive flux, resulting in a reduced macroscopic convection velocity. Numerical validation demonstrates close agreement with the convection-diffusion model over the investigated high-$Pe_r$ conditions, while the classical Taylor-Aris model exhibits substantial deviations. Application of the proposed model to averaged flow velocity inversion further demonstrates improved velocity estimation, particularly in the high-$Pe_r$ regime. These results highlight the importance of accounting for non-classical dispersion for reliable contrast-agent-based arterial blood flow velocimetry and provide new insight into high-$Pe_r$ mass transport.

physics.flu-dyn

Optimization of fluid mixing by reinforcement learning using limit cycles of a dynamical system

We propose a method to overcome the difficulties encountered when applying reinforcement learning to fluid mixing processes. The proposed method has two main features: (i) it does not require detailed measurements of the flow state, and (ii) by effectively exploiting a stable limit cycle of a two-dimensional dynamical system (the Li'enard system), it can stably perform optimization without imposing explicit constraints on the control parameters. As an illustrative example, we optimize a process in which a fluid contained in a cylindrical vessel is mixed by periodically rotating the vessel. The resulting optimal vessel motion is physically reasonable: it reverses its direction of rotation before a solid-body rotation state is established. Furthermore, even when the fluid viscosity increases with time during the mixing process, the method can continuously adapt the control parameters to the changing viscosity.

physics.flu-dyn