Search arXivSearch

arXiv · 2108.10760

Simplified Doppler frequency shift measurement enabled by Serrodyne optical frequency translation

Abstract

A simplified Doppler frequency shift measurement approach based on Serrodyne optical frequency translation is reported. A sawtooth wave with an appropriate amplitude is sent to one phase modulation arm of a Mach-Zehnder modulator in conjunction with the transmitted signal to implement the Serrodyne optical frequency transition, as well as the optical phase modulation of the transmitted signal on the frequency-shifted optical carrier. The echo signal is applied to the other phase modulation arm of the Mach-Zehnder modulator. The optical signals from the two arms are combined in the Mach-Zehnder modulator, whose lower optical sidebands are selected by an optical bandpass filter and then detected in a photodetector. By simply measuring the frequency of the output low-frequency signal, the value and direction of DFS can be determined simultaneously. An experiment is performed. DFS from -100 to 100 kHz is measured for microwave signals from 6 to 17 GHz with a measurement error of less than 0.03 Hz and a measurement stability of 0.015 Hz in 30 minutes when a 500-kHz sawtooth wave is used as the reference.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yang Chen, Taixia Shi. 2021-08-23. Simplified Doppler frequency shift measurement enabled by Serrodyne optical frequency translation. https://arxiv.org/abs/2108.10760

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det