Search arXivSearch

arXiv · 2112.02224

A prototype of a large tunable Fabry-Perot interferometer for solar spectroscopy

Abstract

Large Fabry-Perot Interferometers are used in a variety of astronomical instrumentation, including spectro-polarimeters for 4-meter class solar telescopes. In this work we comprehensively characterize the cavity of a prototype 150 mm Fabry-Perot interferometer, sporting a novel, fully symmetric design. Of note, we define a new method to properly assess the gravity effects on the interferometer's cavity when the system is used in either the vertical or horizontal configuration, both typical of solar observations. We show that the symmetric design very effectively limits the combined effects of pre-load and gravity forces to only a few nm over a 120 mm diameter illuminated surface, with gravity contributing about 2 nm peak-to-valley (0.3 nm rms) in either configuration. We confirm a variation of the tilt between the plates of the interferometer during the spectral scan, which can be mitigated with appropriate corrections to the spacing commands. Finally, we show that the dynamical response of the new system fully satisfies typical operational scenarios. We conclude that large, fully symmetric Fabry-Perot interferometers can be safely used within solar instrumentation in both, horizontal and vertical position, with the latter better suited to limiting the overall volume occupied by such an instrument.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V. Greco, A. Sordini, G. Cauzzi, F. Cavallini, C. Del Vecchio, L. Giovannelli, F. Berrilli, D. Del Moro, K. Reardon, K. Pietraszewski. 2021-12-04. A prototype of a large tunable Fabry-Perot interferometer for solar spectroscopy. https://doi.org/10.1088/1538-3873%2Fac3ec7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM