Search arXivSearch

arXiv · 2112.11630

Size-adjustable Ring-shape Photoacoustic Tomography System

Abstract

Photoacoustic tomography (PAT) combines the advantages of the spectroscopic optical absorption contrast and acoustic resolution with deep penetration, and becomes an important novel biomedical imaging technology for scientific research and clinical diagnosis. In this paper, an imaging size-adjustable PAT system is proposed for clinical applications, which can adapt for different size imaging targets. Comparing with the conventional PAT system setup which with a fixed radius ring shape ultrasound transducer (UT) array, the proposed system, which is based on sectorial ultrasound transducer array (SUTA), is more flexible for different size targets imaging. There are 32 elements for each SUTA, and four SUTAs form a 128-channel UT array for photoacoustic wave detection. The four SUTAs are controlled by four stepper motors, and change the SUTAs distribute positon that adapt for imaging applications. The radius of the proposed system imaging region of interest (ROI) can be adjusted from 50 mm to 90 mm, which is much more flexible than the conventional full ring UT array PAT system. The simulation results generated by the MATLAB k-wave toolbox very well demonstrate the feasibility of the proposed system. To further validate the proposed system for size-adjustable imaging, a vascular mimicking phantom and ex-vivo pork breast with indocyanine green (ICG) injected are imaged to prove its feasibility for clinical applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daohuai Jiang, Yifei Xu, Hengrong Lan, Feng Gao, Fei Gao. 2021-12-22. Size-adjustable Ring-shape Photoacoustic Tomography System. https://arxiv.org/abs/2112.11630

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det