Search arXivSearch

arXiv · 2201.02591

Fieldable Muon Momentum Measurement using Coupled Pressurized Gaseous Cherenkov Detectors

Abstract

Cosmic ray muons present a large part of the radiation background and depending on the application of interest muons can be seen as background noise, e.g., radiation mapping, radiation protection, dosimetry, or as a useful interrogation probe such as cosmic ray muon tomography. It is worth noting recent developments on muon scattering tomography which has emerged as a prospective noninvasive monitoring method for many applications including spent nuclear fuel cask monitoring and geotomography. However, it is still very challenging to measure muon momentum in the field, despite the apparent benefits, without resorting to large and expensive calorimeters, ring imagers, or time of flight detectors. Recent efforts at CNL and INFN have developed large prototypes based on multiple Coulomb scattering coupled with the muon momentum reconstruction algorithms. While these efforts show promise, no portable detectors exist that can measure muon momentum in the field. In this work, we present a new concept for measuring muon momentum using coupled pressurized gaseous Cherenkov radiators. By carefully selecting the gas pressure at each radiator we can optimize the muon momentum threshold for which a muon signal will be detected. This way, a muon passing through the radiators will only trigger those radiators with momentum threshold less than the actual muon momentum. By measuring the presence of Cherenkov signals in each radiator, our system can then estimate the muon momentum. The primary benefit of such a concept is that it can be compact and portable enough so that it can be deployed in the field separately or in combination with existing tomography systems.

Explore related subjects

Keep this discovery

BibTeXRIS

Junghyun Bae, Stylianos Chatzidakis. 2022-01-04. Fieldable Muon Momentum Measurement using Coupled Pressurized Gaseous Cherenkov Detectors. https://arxiv.org/abs/2201.02591

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det