Search arXivSearch

arXiv · 2201.12566

A Wireless and Battery-free Biosensor Based on Parallel Resonators for Monitoring a Wide Range of Biosignals

Abstract

This paper proposes a novel wireless, battery-free, and label-free biosensor for minimally invasive and non-invasive permittivity sensing for applications such as detecting glucose levels in the interstitial dermal fluid. The miniaturized, fully passive sensor is based on two symmetric parallel 0.8 mm$^3$ LC (inductor-capacitor) resonators. Each inductor is integrated with a conductive plate at one of its terminals. The passive sensor's main field is dominant outside the resonators, creating an effective capacitance outside the sensor, unlike reported in previous studies where the effective capacitance was limited to between the resonator lines. The proposed sensor was further analyzed under two different scenarios to change the region of effective capacitance and test its suitability for pressure monitoring, such as wound monitoring; first, by repositioning one of the two resonators, and second, by replacing one of the resonators with a conductive plate. The experimental results confirmed the proposed passive sensor's performance in detecting the glucose concentration in an aqueous solution with a sensitivity of 500 and 46 kHz/(mg/dL) for minimal invasive and non-invasive monitoring, respectively, within the glucose range of 0-500 mg/dL with volume sample requirements as low as 60 $μ$L. Further, by repositioning one of the resonators, the effective capacitance lies inside the passive sensor, making it suitable for wound monitoring. The results indicated that the resonance shift can be made fairly linear with respect to the variation in the separation between the resonators with a sensitivity of 2.5$\times 10^3$ MHz/mm within the separation range of 0.2-0.5 mm, considering separation as the main factor to sense the pressure or healing of the wound.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rehab S. Hassan. 2022-01-29. A Wireless and Battery-free Biosensor Based on Parallel Resonators for Monitoring a Wide Range of Biosignals. https://doi.org/10.1109/tmtt.2022.3194201

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph