Search arXivSearch

arXiv · 2202.08105

Non-linear Cherenkov Muon Spectrometer Using Multi-Layer Pressurized C3F8 Gas Radiators

Abstract

A new Cherenkov muon spectrometer using diversely sized C3F8 gas radiators and nonlinear threshold muon momentum levels was studied using Geant4 simulations. Despite its compact size (<1m3), the performance of the spectrometer was significantly improved over the earlier design (linear and uniform) in two aspects, (i) a stable momentum measurement resolution and (ii) a balanced expected Cherenkov photon yields in all radiators. In addition, CO2 gas radiators are replaced by heavier gas radiators, C3F8, and the sizes of radiators for high momentum levels (low gas pressure) are enlarged to increase the Cherenkov photon yields. Specifically, the absolute momentum resolution, {\sigma}p, for all levels is replaced by the relative momentum resolution, {\sigma}p/p. To demonstrate the functionality of our proposed Cherenkov muon spectrometer, we presented the results of classification rates as a function of muon momentum with various discriminator levels and reconstructed cosmic ray muon spectrum. When the combination of two or more discriminators are used, the average classification rate is 90.08%. In addition, our proposed Cherenkov muon spectrometer successfully reconstructed the cosmic ray muon spectrum and the results show a good agreement with the actual spectrum within 1{\sigma} in most momentum levels.

Explore related subjects

Keep this discovery

BibTeXRIS

Junghyun Bae, Stylianos Chatzidakis. 2022-02-10. Non-linear Cherenkov Muon Spectrometer Using Multi-Layer Pressurized C3F8 Gas Radiators. https://arxiv.org/abs/2202.08105

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det