Search arXivSearch

arXiv · 2203.05910

Development and Commissioning of a Compact Cosmic Ray Muon Imaging Prototype

Abstract

Due to the muon tomography's capability of imaging high Z materials, some potential applications have been reported on inspecting smuggled nuclear materials in customs. A compact Cosmic Ray Muons (CRM) imaging prototype, Lanzhou University Muon Imaging System (LUMIS), is comprehensively introduced in this paper including the structure design, assembly, data acquisition and analysis, detector performance test, and material imaging commissioning etc. Casted triangular prism plastic scintillators (PS) were coupled with Si-PMs for sensitive detector components in system. LUMIS's experimental results show that the detection efficiency of an individual detector layer is about 98%, the position resolution for vertical incident muons is 2.5 mm and the angle resolution is 8.73 mrad given a separation distance of 40.5 cm. Moreover, the image reconstruction software was developed based on the Point of Closest Approach (PoCA) to detect lead bricks as our target. The reconstructed images indicate that the profile of the lead bricks in the image is highly consistent with the target. Subsequently, the capability of LUMIS to distinguish different materials, such as Pb, Cu, Fe, and Al, was investigated as well. The lower limit of response time for rapidly alarming high-Z materials is also given and discussed. The successful development and commissioning of the LUMIS prototype have provided a new solution option in technology and craftsmanship for developing compact CRM imaging systems that can be used in many applications.

Explore related subjects

Keep this discovery

BibTeXRIS

Xujia Luo, Quanxiao Wang, Kemian Qin, Heng Tian, Zhiqiang Fu, Yanwei Zhao, Zhongtao Shen, Hao Liu, Yuanyong Fu, Guorui Liu, Kaiqiang Yao, Xiangping Qian, Jian Rong, Weixiong Zhang, Xiaogang Luo, Chunxian Liu, Xiangsheng Tian, Minghai Yu, Feng Wu, Jingjing Chen, Juntao Liu, Zhiyi Liu. 2022-03-11. Development and Commissioning of a Compact Cosmic Ray Muon Imaging Prototype. https://doi.org/10.1016/j.nima.2022.166720

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det