Search arXivSearch

arXiv · 2203.06060

ROOD-MRI: Benchmarking the robustness of deep learning segmentation models to out-of-distribution and corrupted data in MRI

Abstract

Deep artificial neural networks (DNNs) have moved to the forefront of medical image analysis due to their success in classification, segmentation, and detection challenges. A principal challenge in large-scale deployment of DNNs in neuroimage analysis is the potential for shifts in signal-to-noise ratio, contrast, resolution, and presence of artifacts from site to site due to variances in scanners and acquisition protocols. DNNs are famously susceptible to these distribution shifts in computer vision. Currently, there are no benchmarking platforms or frameworks to assess the robustness of new and existing models to specific distribution shifts in MRI, and accessible multi-site benchmarking datasets are still scarce or task-specific. To address these limitations, we propose ROOD-MRI: a platform for benchmarking the Robustness of DNNs to Out-Of-Distribution (OOD) data, corruptions, and artifacts in MRI. The platform provides modules for generating benchmarking datasets using transforms that model distribution shifts in MRI, implementations of newly derived benchmarking metrics for image segmentation, and examples for using the methodology with new models and tasks. We apply our methodology to hippocampus, ventricle, and white matter hyperintensity segmentation in several large studies, providing the hippocampus dataset as a publicly available benchmark. By evaluating modern DNNs on these datasets, we demonstrate that they are highly susceptible to distribution shifts and corruptions in MRI. We show that while data augmentation strategies can substantially improve robustness to OOD data for anatomical segmentation tasks, modern DNNs using augmentation still lack robustness in more challenging lesion-based segmentation tasks. We finally benchmark U-Nets and transformer-based models, finding consistent differences in robustness to particular classes of transforms across architectures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lyndon Boone, Mahdi Biparva, Parisa Mojiri Forooshani, Joel Ramirez, Mario Masellis, Robert Bartha, Sean Symons, Stephen Strother, Sandra E. Black, Chris Heyn, Anne L. Martel, Richard H. Swartz, Maged Goubran. 2022-03-11. ROOD-MRI: Benchmarking the robustness of deep learning segmentation models to out-of-distribution and corrupted data in MRI. https://arxiv.org/abs/2203.06060

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Hyperspectral Image Restoration and Super-resolution with Physics-Aware Deep Learning for Biomedical Applications

Hyperspectral imaging is a powerful bioimaging tool which can uncover novel insights, thanks to its sensitivity to the intrinsic properties of materials. However, this enhanced contrast comes at the cost of system complexity, constrained by an inherent trade-off between spatial, spectral, and temporal resolution. To overcome this limitation, we present a self-supervised deep learning-based approach that restores and enhances pixel resolution post-acquisition without requiring external training data beyond the images to be restored. Fine-tuned using metrics aligned with the imaging model, our physics-aware method achieves a 16$\times$ pixel super-resolution enhancement and a 12$\times$ imaging speedup without the need of additional training data for transfer learning. Applied to both synthetic and experimental data from five different sample types, including healthy and diseased tissues, we demonstrate that the model preserves biological integrity, as we did not detect systematic loss of biological features or biologically consequential hallucinations in tested datasets. We also concretely demonstrate the model's ability to reveal disease-associated metabolic changes that would otherwise remain undetectable. Furthermore, we provide physical insights into the model's inner workings, paving the way for future refinements that could potentially reveal novel high resolution features in an explainable manner. All methods are available as open-source software on GitHub.

eess.IV

OASIS: Online Adaptive Video Compression via Closed-loop Feedback Control

Computer vision systems are a key building block in an autonomous vehicle, responsible for a range of perception tasks. However, they incur massive data transmission over long communication links from multiple cameras, creating a critical bandwidth and energy bottleneck. Although conventional codecs such as H.264 can reduce data rates, they are ill-suited for real-time vision systems due to high processing latency and energy consumption, as well as their reliance on static user-defined compression settings. In light of these challenges, we propose OASIS, an adaptive video compression framework that integrates lightweight in-sensor compression with task-aware compression ratio control. Based on the real-time task performance, it dynamically updates the optimal compression ratio. Experimental results demonstrate that OASIS generalizes across multiple vision tasks, achieving on average a 6x data compression, 5.8x reduction in link power consumption, and 2.5x reduction in link latency, with at most 1.5% performance degradation.

eess.IV

Echo-E$^3$Net: Efficient Endocardial Spatio-Temporal Network for Ejection Fraction Estimation

Left ventricular ejection fraction (LVEF) is a primary marker of cardiac function. However, routine estimation from endocardial measurements requires manual delineation at end-diastole (ED) and end-systole (ES), a process that is time-consuming and subject to inter-observer variability. Reliable automation is especially valuable for point-of-care ultrasound (POCUS), where computational resources are limited and acquisition quality varies. We propose Echo-E$^3$Net, an anatomy-guided spatio-temporal network that explicitly embeds cardiac anatomy into LVEF prediction. A dual-phase Endocardial Border Detector (E$^2$CBD) uses phase-specific cross-attention to localize ED/ES endocardial landmarks and produce phase-aware landmark embeddings, while an Endocardial Feature Aggregator (E$^2$FA) fuses these embeddings with global statistical descriptors of deep feature maps to refine EF regression. Training is guided by a lightweight geometric loss that uses ED and ES endocardial landmarks to regularize EF prediction. On EchoNet-Dynamic and a PSAX subset of EchoNet-Pediatric, Echo-E$^3$Net attains competitive performance using only 1.55M parameters and 8.05 GFLOPs, an order-of-magnitude compute reduction versus recent baselines, supporting real-time deployment. Our code is publicly available at https://github.com/moeinheidari7829/Echo-E3Net.

eess.IV