Search arXivSearch

arXiv · 2204.03256

Calibration Strategy of the JUNO-TAO Experiment

Abstract

The Taishan Antineutrino Observatory (JUNO-TAO, or TAO) is a satellite detector for the Jiangmen Underground Neutrino Observatory (JUNO). Located near the Taishan reactor, TAO independently measures the reactor's antineutrino energy spectrum with unprecedented energy resolution. To achieve this goal, energy response must be well calibrated. Using the Automated Calibration Unit (ACU) and the Cable Loop System (CLS) of TAO, multiple radioactive sources are deployed to various positions in the detector to perform a precise calibration of energy response. The non-linear energy response can be controlled within 0.6% with different energy points of these radioactive sources. It can be further improved by using $^{12}\rm B$ decay signals produced by cosmic muons. Through the energy non-uniformity calibration, residual non-uniformity is less than 0.2%. The energy resolution degradation and energy bias caused by the residual non-uniformity can be controlled within 0.05% and 0.3%, respectively. In addition, the stability of other detector parameters, such as the gain of each silicon photo-multiplier, can be monitored with a special ultraviolet LED calibration system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hangkun Xu, Angel Abusleme, Nikolay V. Anfimov, Stéphane Callier, Agustin Campeny, Guofu Cao, Jun Cao, Cedric Cerna, Yu Chen, Alexander Chepurnov, Yayun Ding, Frederic Druillole, Andrea Fabbri, Zhengyong Fei, Maxim Gromov, Miao He, Wei He, Yuanqiang He, Joseph yk Hor, Shaojing Hou, Jianrun Hu, Jun Hu, Cédric Huss, Xiaolu Ji, Tao Jiang, Xiaoshan Jiang, Cécile Jolliet, Daozheng Li, Min Li, Ruhui Li, Yichen Li, Caimei Liu, Mengchao Liu, Yunzhe Liu, Claudio Lombardo, Selma Conforti Di Lorenzo, Peizhi Lu, Guang Luo, Mari Stefano M., Xiaoyan Ma, Paolo Montini, Juan Pedro Ochoa-Ricoux, Yatian Pei, Frédéric Perrot, Fabrizio Petrucci, Xiaohui Qian, Abdel Rebii, Bedřich Roskovec, Arsenij Rybnikov, Hans Steiger, Xilei Sun, Pablo Walker, Derun Wang, Meifen Wang, Wei Wang, Zhimin Wang, Diru Wu, Xiang Xiao, Yuguang Xie, Zhangquan Xie, Wenqi Yan, Huan Yang, Haifeng Yao, Mei Ye, Chengzhuo Yuan, Kirill Zamogilnyi, Liang Zhan, Jie Zhang, Shuihan Zhang, Rong Zhao. 2022-05-30. Calibration Strategy of the JUNO-TAO Experiment. https://doi.org/10.1140/epjc%2Fs10052-022-11069-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mortality of ultra-thin LGADs and PiN diodes from high energy deposition

Low Gain Avalanche Diodes are prime candidates for high-resolution timing applications in High Energy Physics, Nuclear science, and several other fields. Operating these devices in high-radiation environments presents various hazards, including the risk of their permanent degradation or destruction caused by effects such as Single Event Burnout. Studies using minimum ionizing particles found a greatly reduced Single Event Burnout risk by operating below a bias voltage corresponding to an average electric field of 12 V/$μ$m - however, as high energy particle colliders produce a wide energy spectrum of radiation, it is crucial to understand this phenomenon and other possible damage mechanisms at energy deposition levels greater than those of minimum ionizing particles. This was achieved by pre-irradiating LGADs and PiN diodes with active thicknesses of 20, 30, and 50 $μ$m up to 1.5 $\times$ 10$^{15}$ $\mathrm{n_{eq}/cm^2}$, and exposing them to beams of protons and heavy ions (C, O, Fe, Au) at the BNL Tandem van de Graaff accelerator. Several mortality categories were observed, defined by different electrical and mechanical damage signatures. This furthers our understanding of permanent radiation damage of silicon devices, crucial towards mitigating Single Event Burnout and other damage mechanisms to safely operate future detectors.

physics.ins-det

Small but Tubby: A Magnetic Loop Antenna Made from 100 mm Copper Tubing

This paper presents the electrical model, key equations, and practical construction of a small transmitting magnetic loop antenna built from unusually large 100 mm diameter copper tubing. The large conductor surface area and wide-area transitions to the vacuum capacitors were designed to minimize resistive losses. The frequency range from 1.8 MHz to 31 MHz is unusually wide. Frequency, impedance matching, and azimuth are all adjusted automatically by servo motors. Indoor losses originate predominantly from near-field coupling to the environment rather than from the antenna itself. Temperature-rise measurements confirm that the bulk of the dissipated power is absorbed by the environment, not by the antenna components. The conducted H-field measurements demonstrate good agreement between the measured H-field and the theoretical free-space H-field calculated from the antenna geometry and an estimated loop current. The loop current was estimated from the measured antenna bandwidth and the applied transmit power. The antenna was developed for indoor operation where outdoor installation is not possible.

physics.ins-det

Construction and characterisation of the DarkSide-20k veto silicon photo-multiplier tiles

Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment, designed to perform direct dark matter searches using liquid argon as the target material, employs SiPM technology to detect interactions in the active detector volumes, including the central dual-phase Time Projection Chamber and the Inner and Outer Veto volumes. The vetoes are designed to discriminate against radiogenic neutron and cosmic muon backgrounds associated with the dark matter search. This paper describes the completed production and test protocols for the "Veto Tiles" (called vTiles, arrays of 24 SiPMs integrated on a printed circuit board providing the power distribution and signal amplification); 16 vTiles are grouped into "Veto Photo-Detector Units" to instrument the Inner Veto volume. Each vTile underwent detailed testing at room and cryogenic temperatures, confirming stable operation, high signal-to-noise ratio, and low radioactive contamination, demonstrating the robustness of the proposed design for cryogenic conditions. The final production yield exceeded 87%, surpassing the 80% requirement and corresponding to 1920 Veto Tiles to populate 120 Veto Photo-Detector Units, plus an additional 6% as spares.

physics.ins-det