Search arXivSearch

arXiv · 2204.12739

Analysis of the data from photoelectric gas polarimeters

Abstract

We review the tools and procedures for the analysis of the data collected by X-ray photoelectric gas polarimeters, like the ones on-board the Imaging X-ray Polarimetry Explorer (IXPE). Although many of such tools are in principle common with polarimeters working at other energy bands, the peculiar characteristics and performance of these devices require a specific approach. We will start from the analysis of the raw data read-out from this kind of instruments, that is, the image of the track of the photoelectron. We will briefly present how such images are processed with highly-specialized algorithms to extract all the information collected by the instrument. These include energy, time of arrival and, possibly, absorption point of the photon, in addition to the initial direction of emission of the photoelectron. The last is the quantity relevant for polarimetry, and we will present different methods to obtain the polarization degree and angle from it. A simple method, used extensively especially during the development phase of X-ray photoelectric gas polarimeters, is based on the construction and fitting of the azimuthal distribution of the photoelectrons. We will discuss that there are several reasons to prefer an analysis based on Stokes parameters, especially when one wants to analyze measurements of real, i.e., not laboratory, sources. These are quantities commonly used at all wavelengths because they are additive, and then operations like background subtraction or the application of calibration are trivial to apply. We will summarize how Stokes parameters can be used to adapt current spectroscopy software based on forward folding fitting to perform spectro-polarimetry. Moreover, we will derive how to properly associate the statistical uncertainty on a polarimetry measurement and the relation with another statistical indicator, which is in the minimum detectable polarization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fabio Muleri. 2022-04-27. Analysis of the data from photoelectric gas polarimeters. https://doi.org/10.1007/978-981-16-4544-0_143-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM