Search arXivSearch

arXiv · 2205.01866

Correlated Read Noise Reduction in Infrared Arrays Using Deep Learning

Abstract

We present a new procedure rooted in deep learning to construct science images from data cubes collected by astronomical instruments using HxRG detectors in low-flux regimes. It improves on the drawbacks of the conventional algorithms to construct 2D images from multiple readouts by using the readout scheme of the detectors to reduce the impact of correlated readout noise. We train a convolutional recurrent neural network on simulated astrophysical scenes added to laboratory darks to estimate the flux on each pixel of science images. This method achieves a reduction of the noise on constructed science images when compared to standard flux-measurement schemes (correlated double sampling, up-the-ramp sampling), which results in a reduction of the error on the spectrum extracted from these science images. Over simulated data cubes created in a low signal-to-noise ratio regime where this method could have the largest impact, we find that the error on our constructed science images falls faster than a $1/\sqrt{N}$ decay, and that the spectrum extracted from the images has, averaged over a test set of three images, a standard error reduced by a factor of 1.85 in comparison to the standard up-the-ramp pixel sampling scheme. The code used in this project is publicly available on GitHub

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Guillaume Payeur, Étienne Artigau, Laurence Perreault-Levasseur, René Doyon. 2022-05-04. Correlated Read Noise Reduction in Infrared Arrays Using Deep Learning. https://doi.org/10.3847/1538-3881%2Fac69d2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM