Search arXivSearch

arXiv · 2205.04167

Performance assessment of medical and non-medical CPAP interfaces used during the COVID-19 pandemic

Abstract

Background: At the beginning of 2020, a high number of COVID-19 cases affected Italy in a short period, causing a difficult supply of medical equipment. To deal with the problem, many healthcare operators readapted different masks to medical devices, but no experiment was conducted to evaluate their performance. The aims of our study were: to assess the performances of three masks and a CPAP helmet in their original configuration and after modifications, in the maintenance of mean pressure and half-amplitude variations using different PEEP valves and to analyse the impact of antibacterial (AB) or antibacterial-viral (ABV) pre-valve PEEP filters on the effective PEEP delivered to the patients. Four pressure ports were installed on each mask (three on helmet), mean values and half amplitudes of pressure were recorded. Tests were performed with any, AB, ABV filter before the PEEP valve. CPAP helmet was the most efficient interface producing more stable mean pressure and less prominent half-amplitude variations but the non-medical masks, especially after the modifications, maintained a stable mean pressure value with only a moderate increase of half-amplitude. The use of AB and ABV filters, produced respectively an increase of 2,23% and 16.5% in mean pressure, compared to no filter condition. CPAP helmet is the most reliable interface in terms of detected performance, but readapted masks can assure almost a similar performance. The use of ABV filters before the PEEP valve significantly increases the detected mean pressure while the AB filters have almost a neutral effect.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Marco Marini, Lorenzo Capponi, Ilaria Battistoni, Tommaso Tocci, Giulio Tribbiani, Francesco Merante, Matteo Francioni, Maria Vittoria Matassini, Giulia Pongetti, Matilda Skhoza, Luca Angelini, Roberto Marsili, Marco Mazzanti, Gian Piero Perna, Gianluca Rossi, Alberto Gili. 2022-05-09. Performance assessment of medical and non-medical CPAP interfaces used during the COVID-19 pandemic. https://arxiv.org/abs/2205.04167

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP