Search arXivSearch

arXiv · 2206.10616

Bioelectric Registration of Electromagnetic Tracking and Preoperative Volume Data

Abstract

For minimally invasive endovascular surgery, the localization of catheters and guidewires inside the human body is essential. Electromagnetic (EM) tracking is one technology that allows localizing such surgical instruments. For localizing intra-operatively EM-tracked instruments with respect to preoperative volume data, it is necessary to bring pre- and intraoperative imaging into the same coordinate frame. In most existing solutions, such registration requires additional interactions, modifying the procedure's original workflow. We propose a new method taking advantage of Bioelectric signals to initialize and register preoperative volumes to the EM tracking system without significantly changing the interventional workflow. We envision the most natural use-case of our concept in cardiac electrophysiology (EP) procedures, in which EP catheters are already equipped with all the necessary sensing, including electric sensing for the measurement of electrophysiological signals and EM tracking for catheter localization. We use EP catheters for Bioelectric sensing to detect local features of the vasculature while advancing the catheter inside the human body. Such features can be automatically labeled before the procedure within the preoperative data. The combination of Bioelectric and EM tracking can localize vascular features such as bifurcations and stenosis within the EM tracking space. Mapping them to preoperative data automatically registers patients' CT space to EM tracking. The proposed registration process is entirely based on Bioelectric sensed features, with no need for external markers or other interventional imaging devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ardit Ramadani, Heiko Maier, Felix Bourier, Christian Meierhofer, Peter Ewert, Heribert Schunkert, Nassir Navab. 2022-06-20. Bioelectric Registration of Electromagnetic Tracking and Preoperative Volume Data. https://arxiv.org/abs/2206.10616

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph