Search arXivSearch

arXiv · 2208.05868

TotalSegmentator: robust segmentation of 104 anatomical structures in CT images

Abstract

We present a deep learning segmentation model that can automatically and robustly segment all major anatomical structures in body CT images. In this retrospective study, 1204 CT examinations (from the years 2012, 2016, and 2020) were used to segment 104 anatomical structures (27 organs, 59 bones, 10 muscles, 8 vessels) relevant for use cases such as organ volumetry, disease characterization, and surgical or radiotherapy planning. The CT images were randomly sampled from routine clinical studies and thus represent a real-world dataset (different ages, pathologies, scanners, body parts, sequences, and sites). The authors trained an nnU-Net segmentation algorithm on this dataset and calculated Dice similarity coefficients (Dice) to evaluate the model's performance. The trained algorithm was applied to a second dataset of 4004 whole-body CT examinations to investigate age dependent volume and attenuation changes. The proposed model showed a high Dice score (0.943) on the test set, which included a wide range of clinical data with major pathologies. The model significantly outperformed another publicly available segmentation model on a separate dataset (Dice score, 0.932 versus 0.871, respectively). The aging study demonstrated significant correlations between age and volume and mean attenuation for a variety of organ groups (e.g., age and aortic volume; age and mean attenuation of the autochthonous dorsal musculature). The developed model enables robust and accurate segmentation of 104 anatomical structures. The annotated dataset (https://doi.org/10.5281/zenodo.6802613) and toolkit (https://www.github.com/wasserth/TotalSegmentator) are publicly available.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jakob Wasserthal, Hanns-Christian Breit, Manfred T. Meyer, Maurice Pradella, Daniel Hinck, Alexander W. Sauter, Tobias Heye, Daniel Boll, Joshy Cyriac, Shan Yang, Michael Bach, Martin Segeroth. 2023-06-16. TotalSegmentator: robust segmentation of 104 anatomical structures in CT images. https://doi.org/10.1148/ryai.230024

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

JEVQA - Video Quality from Metadata, Bitstream, and Pixel Features with a General-Purpose Decision Model

Instrumental quality models for video quality prediction are usually trained for a fixed set of codecs or other input features, and every new input variable requires retraining. Novel, general-purpose decision models can answer questions without task-specific training, but it is unclear whether they can judge video quality. We evaluate Jev, a commercial ``System One'' model that returns probability distributions over a provided answer scale, as a zero-shot video quality model. We call the resulting method JEVQA. In a first study on 1,936 AV1, H.264, HEVC, and VP9 encodes of 22 sources, scored against VMAF as ground truth, using encoding metadata only, JEVQA reached a Pearson correlation of 0.737, on par with the standardized ITU-T P.1204.1 model (0.733). Giving the model bitstream data raised the accuracy to 0.797, and combined pixel-based and bitstream features raised it to 0.824. A pixel-only variant failed in our tests. In a second study, using H.264, HEVC, and VP9 encodes in the AVT-VQDB-UHD-1 database, the metadata-only model reached a correlation of 0.879 with MOS, close to P.1204.1 (0.898). Bitstream statistics did not help there. Our results show that trained models on the same features remain clearly ahead in both studies, but that zero-shot classifiers are promising.

eess.IV

When is a closed-form RGB->S/P ratio adequate? A hyperspectral characterization on natural scenes for mesopic display

Mesopic and low-light display transforms require, as their driving signal, a per-pixel scotopic-to-photopic luminance ratio (S/P); the exact spectral S/P is unavailable for ordinary RGB content, so a low-cost closed form that estimates S/P from a linear-RGB triplet is used in its place. Such closed forms exist but have been characterized only on narrowband / LED sources, i.e. spectrally sparse spectra, where a relative error of ~41% has been reported for a three-channel projection. Display content, however, is natural and broadband. We ask whether the same closed form is adequate there, using per-pixel spectral S/P from hyperspectral imagery as ground truth. On a daylight radiance time-series, a six-scalar closed form (three photopic and three scotopic channel weights) reproduces spectral S/P with a median error of ~0.07 that is time-invariant once the RGB input is chromatically adapted to D65; evaluated in un-adapted sRGB the error instead carries a color-temperature tilt across illuminants (~0.19), so adaptation is the enabling step for this use case. The result generalizes to an independent fifty-scene set (pooled median 0.024; 45/50 scenes within a pre-registered 0.10 band), with the few exceedances concentrated in saturated, spectrally-peaky surfaces that approach the narrowband regime (floral close-ups in this set). The scotopic weight vector is shown to be primary-model dependent, but the value used here is corroborated by a primary-free XYZ projection, and the median error stays within the band across all principled coefficient choices. We do not claim observer-validated appearance fidelity or adequacy on narrowband sources; both are out of scope. Both outcomes follow from the same three-channel projection: it is overwhelmed by spectrally sparse inputs and adequate on spectrally smooth ones.

eess.IV

Recurrent Convolutional Neural Networks for LiDAR-Based Attitude Initialization of Rotating Spacecraft

Accurate attitude estimation is essential for autonomous in-orbit servicing and proximity operations. This work proposes a Recurrent Convolutional Neural Network (RCNN) used in coarse attitude initialization of known, possibly tumbling spacecraft using LiDAR-derived depth images. By processing temporal sequences of 2D point-cloud projections, the RCNN effectively handles symmetries, occlusions, and degraded sensing. Simulations across various spacecraft geometries, angular velocities, and ranges show that the RCNN yields lower initialization errors and higher convergence rates than conventional CNN baseline within the adopted experimental framework, with performance varying across angular velocity conditions.

eess.IV