Search arXivSearch

arXiv · 2208.12881

Multi-Modality Cardiac Image Computing: A Survey

Abstract

Multi-modality cardiac imaging plays a key role in the management of patients with cardiovascular diseases. It allows a combination of complementary anatomical, morphological and functional information, increases diagnosis accuracy, and improves the efficacy of cardiovascular interventions and clinical outcomes. Fully-automated processing and quantitative analysis of multi-modality cardiac images could have a direct impact on clinical research and evidence-based patient management. However, these require overcoming significant challenges including inter-modality misalignment and finding optimal methods to integrate information from different modalities. This paper aims to provide a comprehensive review of multi-modality imaging in cardiology, the computing methods, the validation strategies, the related clinical workflows and future perspectives. For the computing methodologies, we have a favored focus on the three tasks, i.e., registration, fusion and segmentation, which generally involve multi-modality imaging data, \textit{either combining information from different modalities or transferring information across modalities}. The review highlights that multi-modality cardiac imaging data has the potential of wide applicability in the clinic, such as trans-aortic valve implantation guidance, myocardial viability assessment, and catheter ablation therapy and its patient selection. Nevertheless, many challenges remain unsolved, such as missing modality, combination of imaging and non-imaging data, and uniform analysis and representation of different modalities. There is also work to do in defining how the well-developed techniques fit in clinical workflows and how much additional and relevant information they introduce. These problems are likely to continue to be an active field of research and the questions to be answered in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lei Li, Wangbin Ding, Liqun Huang, Xiahai Zhuang, Vicente Grau. 2022-08-26. Multi-Modality Cardiac Image Computing: A Survey. https://arxiv.org/abs/2208.12881

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

SCI-Mamba: Unsupervised Learning based Low-Light Image Enhancement for Non-Cooperative Spacecraft

Low-light visual perception acts as the core visual foundation for on-orbit servicing missions targeting non-cooperative spacecraft, supporting autonomous rendezvous, pose estimation, component detection and robotic capture operations. Spaceborne imagery suffers from severe low-light degradation, while the extreme scarcity of paired normal/low-light space samples severely limits the generalization capacity of supervised enhancement algorithms. To address this practical bottleneck, this paper proposes SCI-Mamba, an unsupervised enhancement network for low-light orbital spacecraft observations. The proposed framework unites self-calibrated unsupervised learning, linear-complexity VMamba architecture and Retinex physical priors, delivering a lightweight enhancement pipeline adaptable to resource-limited spaceborne hardware. We construct Space Dark-1.0, a dedicated low-light spacecraft dataset integrating real orbital footage, darkroom hardware-in-the-loop measurements and physically constrained synthetic data covering diverse illumination, motion and attitude conditions. Comprehensive comparisons with CNN-, Transformer- and prevailing Mamba-based approaches verify the advantages of SCI-Mamba in visual authenticity, color fidelity and inference speed. The proposed framework provides a practical low-light enhancement solution for close-proximity non-cooperative space operations. The code is available at https://github.com/bitswh/SCI-Mamba

eess.IV

Recursive Uncertainty-Gated Image Registration for Learning-based Algorithms

Conventional image registration algorithms are robust to domain shifts and achieve low errors, but they are slow and computationally expensive. Deep-learning methods are efficient at inference-time, but face challenges in out-of-domain samples. We propose Recursive Uncertainty-Gated Image Registration (RUGI), an algorithm for iteratively refining deformation fields predicted by learning-based registration models. At each iteration, the registration model predicts an incremental deformation, and a gating map modulates the update. Refinements are hence concentrated in regions that remain difficult to register. We explore two gating strategies: a learned uncertainty-based approach and an image residual error approach. We evaluate RUGI on cardiac MRI and echocardiography datasets and show consistent improvements over single-step inference. Ablation experiments demonstrate that iterative refinement alone improves registration, but informative spatial gating provides a significant additional benefit. The error-gated variant of RUGI can also be applied directly to existing pretrained models; applied to VoxelMorph, TransMorph, and CycleMorph, it yields MSE reductions of 27-37% with no modification to the original training procedure. The improvements in registration performance are reflected in decreased errors in ejection fraction estimation relative to ground truths. These results demonstrate that spatially selective iterative refinement provides an effective strategy to improve registration accuracy at inference-time.

eess.IV

STAMBRIDGE: Spectral-Temporal Amplitude-aware Mid-Feature Bridge for EEG Visual Decoding

Electroencephalography (EEG) visual decoding remains challenging due to the modality gap between low-SNR neural signals and highly structured vision--language spaces, making direct cross-modal alignment unstable. To address this, we propose STAMBRIDGE, a versatile two-stage framework that sequentially tackles feature conditioning and cross-modal alignment. First, we introduce a Spectral-Temporal Amplitude-aware Modulation (STAM) to extract well-conditioned EEG representations. By replacing hard frequency masking with amplitude-derived soft channel weighting and multi-scale temporal convolutions, STAM explicitly preserves frequency-aware transients while reducing the risk of time-domain ringing artifacts. Building upon these robust neural features, we further introduce a model-agnostic Mid-Feature Semantic Bridge (MFSB) that constructs a regularized intermediate space through directed cross-modal interactions, enabling staged distillation and more stable semantic alignment. Experiments on the THINGS-EEG benchmark show competitive 200-way zero-shot retrieval performance, with 34.50\% Top-1 and 65.95\% Top-5 accuracy. In addition, embeddings learned by STAMBRIDGE produce semantically coherent image reconstructions with a diffusion model, demonstrating robust EEG-to-vision semantic alignment. The code is available at: https://github.com/thabeatmjh/STAMBRIDGE.

eess.IV