Search arXivSearch

arXiv · 2209.03541

Practical use of reactor anti-neutrinos for nuclear safeguard in Vietnam

Abstract

One of the most abundant man-made sources of low energy (few~MeVs) neutrinos, reactor neutrino, is not only useful for studying neutrino properties, but it is also used in practical applications. In this study, we investigate the practical use of reactor neutrino detectors for nuclear safeguard in Vietnam, specifically at the Dalat Nuclear Reactor, a future research facility, and presumably commercial reactors with 500~kW, 10~MW, and 1000~MW thermal powers, respectively. We compute the rate of observed inverted beta decay events, as well as the statistical significance of extracting isotope composition under the practical assumptions of detector mass, detection efficiency, and background level. We find that a 1-ton detector mass can allow us to detect the reactor's on-off transition state from a few hours to a few days, depending on the standoff distance and reactor thermal power. We investigate how background and energy resolution affect the precision of the extracted weapon-usable ${}^{239}\text{Pu}$ isotope. We conclude that in order to distinguish the 10\% variation of the ${}^{239}\text{Pu}$ in the 10~MW thermal power reactor, a 1-ton detector placed 50~m away must achieve 1\% background level. Increasing the statistics by using a 10x larger detector or placing it $\sqrt{10}$ times closer to the reactor alleviates the requirement of the background level to 10\%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Son Cao, T. V. Ngoc, N. T. Hong Van, P. T. Quyen. 2022-09-08. Practical use of reactor anti-neutrinos for nuclear safeguard in Vietnam. https://arxiv.org/abs/2209.03541

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Charge-dependent atmospheric muon flux at 17 GV geomagnetic cutoff with the mini-ICAL detector

The Iron CALorimeter (ICAL) detector at the India-Based Neutrino Observatory (INO) was conceived as an underground experiment designed to measure atmospheric neutrino oscillation parameters. As part of the R\&D programme, a scaled prototype (mini-ICAL), 85\,ton, approximately 1/600$^{\mathrm{th}}$ the mass of the full detector, was constructed at the IICHEP Transit Campus, Madurai (altitude 150\,m; latitude 9.9372$^\circ$\,N; longitude 78.013$^\circ$\,E; geomagnetic latitude 1.44$^\circ$\,N; vertical cutoff rigidity 17\,GV) and operated between 2018 and 2022. The prototype enabled measurements of charge-dependent cosmic muon spectra in the vicinity of the geomagnetic equator and provided an important validation of detector performance, reconstruction algorithms, and simulation frameworks for the ICAL experiment. Differential fluxes of $μ^{-}$ and $μ^{+}$ were measured over the momentum range $\sim$\,1--5\,GeV/c. The obtained momentum spectra are systematically lower than those reported at sites with smaller geomagnetic cutoff rigidities, consistent with the suppression of low- and intermediate-rigidity primary cosmic rays at the 17\,GV cutoff. The measurements are compared with predictions from different hadronic interaction models available in CORSIKA simulations.

hep-ex

Laboratory constraints on peV-scale mass splitting between ordinary and sterile neutron states

Sterile states of matter, represented by a parallel ``mirror'' sector, may contribute to the observed dark matter in the Universe. We investigated the parameter space of neutron $(n)$ to mirror-neutron $(n')$ oscillations, in the case where the two states are not necessarily mass-degenerate, taking into account interactions in the mirror sector. By tuning the magnitude of an applied magnetic-field in the range $5~μ\mathrm{T} < B < 360~μ\mathrm{T}$ to corresponding resonance conditions for finite mass splitting, we derive exclusion limits for the $n-n'$ oscillation time constant reaching about $20~\text{s}$ over the mass-difference range $0.3 - 22~\text{peV}$. In parts of this parameter range, our limits exceed the model-dependent neutron-star-cooling bound, providing the first experimental constraints in this scenario that are more stringent than this astrophysical estimate.

hep-ex

Search for the $^{16}\text{O}(ppp) \rightarrow ^{13}\text{C} π^+ π^+ e^+$ Decay Mode in Super-Kamiokande Using Machine Learning Techniques

We report a new partial lifetime limit of $4.2 \times 10^{32}$ years for the trinucleon decay mode $^{16}\text{O}(ppp) \rightarrow ^{13}\text{C} π^+ π^+ e^+$, obtained from a search conducted using the Super-Kamiokande detector with 0.401 megaton-years of exposure across five operational periods (SK-I: 1996--2001, SK-II: 2002--2005, SK-III: 2006--2008, SK-IV: 2008--2018, SK-V: 2019--2020). This represents an improvement of six orders of magnitude over previous experimental constraints. The analysis utilizes a convolutional neural network (CNN) incorporating an attention mechanism---a computational technique that enables the model to focus on the most relevant regions of Cherenkov ring patterns---to enhance event classification, thereby improving the sensitivity of the search. This is the first application of a CNN to a nucleon decay search in Super-Kamiokande. Furthermore, the large dataset available in Super-Kamiokande (hereafter "SK") strengthens the statistical power of the study, enabling a more stringent constraint than those set by prior experiments.