Search arXivSearch

arXiv · 2209.09455

An all-photonic, dynamic device for flattening the spectrum of a laser frequency comb for precise calibration of radial velocity measurements

Abstract

Laser frequency combs are fast becoming critical to reaching the highest radial velocity precisions. One shortcoming is the highly variable brightness of the comb lines across the spectrum (up to 4-5 orders of magnitude). This can result in some lines saturating while others are at low signal and lost in the noise. Losing lines to either of these effects reduces the precision and hence effectiveness of the comb. In addition, the brightness of the comb lines can vary with time which could drive comb lines with initially reasonable SNR's into the two regimes described above. To mitigate these two effects, laser frequency combs use optical flattener's. Flattener's are typically bulk optic setups that disperse the comb light with a grating, and then use a spatial light modulator to control the amplitude across the spectrum before recombining the light into another single mode fiber and sending it to the spectrograph. These setups can be large (small bench top), expensive (several hundred thousand dollars) and have limited stability. To address these issues, we have developed an all-photonic spectrum flattener on a chip. The device is constructed from optical waveguides on a SiN chip. The light from the laser frequency comb's output optical fiber can be directly connected to the chip, where the light is first dispersed using an arrayed waveguide grating. To control the brightness of each channel, the light is passed through a Mach-Zehnder interferometer before being recombined with a second arrayed waveguide grating. Thermo-optic phase modulators are used in each channel before recombination to path length match the channels as needed. Here we present the results from our first generation prototype. The device operates from 1400-1800 nm (covering the H band), with 20, 20 nm wide channels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nemanja Jovanovic, Pradip Gatkine, Boqiang Shen, Maodong Gao, Nick Cvetojevic, Katarzyna Ławniczuk, Ronald Broeke, Charles Beichman, Stephanie Leifer, Jeffery Jewell, Gautam Vasisht, Dimitri Mawet. 2022-09-20. An all-photonic, dynamic device for flattening the spectrum of a laser frequency comb for precise calibration of radial velocity measurements. https://doi.org/10.1117/12.2630301

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Scale Contrastive Attention for Light-Curve Representation Learning

Current and next-generation time-domain surveys demand automated techniques capable of analyzing millions of light curves, observed in multiple filters, without relying on exhaustive human annotation or scarce spectroscopic follow-up. We present Astra-CLR, an attention-based, self-supervised contrastive learning framework which enables the representation of raw light curves into a highly discriminative latent space. Pre-trained on $\sim$2.1 million unlabeled Zwicky Transient Facility light curves, the framework utilizes partial light curves as input sequences to generate asymmetric, multi-scale temporal views (explicitly contrasting shorter sequences against longer ones) forcing the network to learn a robust "local-to-global" mapping strategy. Furthermore, we introduce a novel multi-view late fusion architecture that extends the model to efficiently handle longer light curves with larger numbers of observations while accommodating the different cadences associated with each filter. The discriminatory power of the resulting representations was evaluated by using them as input to a Multinomial Logistic Regression classifier, trained to identify 12 broad classes of variability. Final accuracy achieved $\sim 0.70$. When applying a label-efficient, partial top-layer fine-tuning strategy, the topological structure of the latent space is significantly refined, boosting results to $\sim$0.77. Astra-CLR is the first publicly available multi-filter time-series Transformer trained exclusively on real ZTF light curves. Results presented here demonstrate that it provides an ideal foundation for the development of end-to-end pipelines, taking into account color evolution and respecting the inhomogeneous nature of astronomical light curve sampling.

astro-ph.IM

Combining astrometry with pulsar timing: the first joint analysis of very low frequency gravitational waves

The pHz to sub-nHz GW regime remains largely unexplored but is crucial for mapping the early inspiral stage of SMBHBs and probing early-Universe physics. Astrometry and pulsar timing offer orthogonal and deeply complementary secular observables to investigate this frequency band. We aim to present the first joint data analysis combining real astrometric proper motions with binary pulsar timing, to search for and constrain continuous gravitational waves (CWs) sourced by SMBHBs in the ultra-low-frequency regime ($10^{-12} \le f_{GW} \le10^{-9} Hz$). We employ a Bayesian model selection and upper limit estimation framework to combine apparent proper motion displacements of $\sim 1.5 \times 10^6$ quasars from the Gaia CRF3 catalog with the line-of-sight orbital period derivatives ($\dot{P}_b$) of 11 high-precision binary pulsars. To prevent spurious detections, we heavily model instrumental and astrophysical systematics: we propagate the Galactic potential uncertainty for pulsars via Monte Carlo simulations and perform a Vector Spherical Harmonics (VSH) decomposition up to the octupole order (l=3) for quasars. We find no statistically significant evidence for a CWs signal in the joint analysis ($\ln B_{joint} = -0.42 \pm 0.03$). In the absence of detection, we set the tightest constraints to date on CW strain in the pHz band, yielding a 95% upper limit of $h_0\le6.4x10^{-11}$ at a reference frequency of $f_{ref} = 4 \times 10^{-10}$ Hz. The combined dataset achieves full sky coverage and improves single-dataset upper limits by 20%-30%. Combining orthogonal observables successfully breaks spatial degeneracies intrinsic to isolated searches. Furthermore, forecasts from inj.-rec. indicate that with the extended temporal baseline and reduced uncertainties of the upcoming Gaia DR4, this joint framework is poised to break the $h_0 < 10^{-11}$ upper limit barrier for sub-nHz CWs.

astro-ph.IM

Bayesian classification of astronomical spectra with class uncertainties

Context: We developed a probabilistic machine learning method with the aim of performing the O(10)-way classification of low- and high-resolution spectra of stellar and extragalactic targets for the upcoming 4MOST survey. In fulfilment of the survey requirements, this method should be able to express uncertainty in the input data as well as uncertainty introduced in its prediction. Aims: Four different methods are explored: (1) convolutional neural networks (CNNs), (2) the Dirichlet distribution, (3) Monte Carlo dropout (MCD), (4) Bayesian neural Networks (BNNs) + variational inference (VI). Training and validation was performed using labelled spectra from the SDSS database and a custom 4MOST mock dataset. All the methods were compared in terms of the same metrics: accuracy, area under the curve (AUC), expected calibration error (ECE), Shannon entropy, negative log-likelihood (NLL), Brier score, training time, and inference time. Methods: A CNN with simple architecture and about 20,000 parameters was trained to achieve classification accuracies of 91.5% on SDSS data and 92.8% on 4MOST mock data. The direct Dirichlet prediction and VI models tested provide uncertainties on class membership probabilities, but they confuse classes more often. The MCD on a CNN is found to be the most suitable; it boosts the point-estimate accuracies to 92.6% and 93.9%, while still providing fast training and sufficiently fast inference. Compared to a standard CNN, the method additionally provides well-calibrated uncertainties at marginal extra cost.

astro-ph.IM