Artificial Intelligence-Based Image Reconstruction in Cardiac Magnetic Resonance

Abstract

Artificial intelligence (AI) and Machine Learning (ML) have shown great potential in improving the medical imaging workflow, from image acquisition and reconstruction to disease diagnosis and treatment. Particularly, in recent years, there has been a significant growth in the use of AI and ML algorithms, especially Deep Learning (DL) based methods, for medical image reconstruction. DL techniques have shown to be competitive and often superior over conventional reconstruction methods in terms of both reconstruction quality and computational efficiency. The use of DL-based image reconstruction also provides promising opportunities to transform the way cardiac images are acquired and reconstructed. In this chapter, we will review recent advances in DL-based reconstruction techniques for cardiac imaging, with emphasis on cardiac magnetic resonance (CMR) image reconstruction. We mainly focus on supervised DL methods for the application, including image post-processing techniques, model-driven approaches and k-space based methods. Current limitations, challenges and future opportunities of DL for cardiac image reconstruction are also discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chen Qin, Daniel Rueckert. 2022-09-21. Artificial Intelligence-Based Image Reconstruction in Cardiac Magnetic Resonance. https://doi.org/10.1007/978-3-030-92087-6_14

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

SCI-Mamba: Unsupervised Learning based Low-Light Image Enhancement for Non-Cooperative Spacecraft

Low-light visual perception acts as the core visual foundation for on-orbit servicing missions targeting non-cooperative spacecraft, supporting autonomous rendezvous, pose estimation, component detection and robotic capture operations. Spaceborne imagery suffers from severe low-light degradation, while the extreme scarcity of paired normal/low-light space samples severely limits the generalization capacity of supervised enhancement algorithms. To address this practical bottleneck, this paper proposes SCI-Mamba, an unsupervised enhancement network for low-light orbital spacecraft observations. The proposed framework unites self-calibrated unsupervised learning, linear-complexity VMamba architecture and Retinex physical priors, delivering a lightweight enhancement pipeline adaptable to resource-limited spaceborne hardware. We construct Space Dark-1.0, a dedicated low-light spacecraft dataset integrating real orbital footage, darkroom hardware-in-the-loop measurements and physically constrained synthetic data covering diverse illumination, motion and attitude conditions. Comprehensive comparisons with CNN-, Transformer- and prevailing Mamba-based approaches verify the advantages of SCI-Mamba in visual authenticity, color fidelity and inference speed. The proposed framework provides a practical low-light enhancement solution for close-proximity non-cooperative space operations. The code is available at https://github.com/bitswh/SCI-Mamba

eess.IV

Recursive Uncertainty-Gated Image Registration for Learning-based Algorithms

Conventional image registration algorithms are robust to domain shifts and achieve low errors, but they are slow and computationally expensive. Deep-learning methods are efficient at inference-time, but face challenges in out-of-domain samples. We propose Recursive Uncertainty-Gated Image Registration (RUGI), an algorithm for iteratively refining deformation fields predicted by learning-based registration models. At each iteration, the registration model predicts an incremental deformation, and a gating map modulates the update. Refinements are hence concentrated in regions that remain difficult to register. We explore two gating strategies: a learned uncertainty-based approach and an image residual error approach. We evaluate RUGI on cardiac MRI and echocardiography datasets and show consistent improvements over single-step inference. Ablation experiments demonstrate that iterative refinement alone improves registration, but informative spatial gating provides a significant additional benefit. The error-gated variant of RUGI can also be applied directly to existing pretrained models; applied to VoxelMorph, TransMorph, and CycleMorph, it yields MSE reductions of 27-37% with no modification to the original training procedure. The improvements in registration performance are reflected in decreased errors in ejection fraction estimation relative to ground truths. These results demonstrate that spatially selective iterative refinement provides an effective strategy to improve registration accuracy at inference-time.

eess.IV

STAMBRIDGE: Spectral-Temporal Amplitude-aware Mid-Feature Bridge for EEG Visual Decoding

Electroencephalography (EEG) visual decoding remains challenging due to the modality gap between low-SNR neural signals and highly structured vision--language spaces, making direct cross-modal alignment unstable. To address this, we propose STAMBRIDGE, a versatile two-stage framework that sequentially tackles feature conditioning and cross-modal alignment. First, we introduce a Spectral-Temporal Amplitude-aware Modulation (STAM) to extract well-conditioned EEG representations. By replacing hard frequency masking with amplitude-derived soft channel weighting and multi-scale temporal convolutions, STAM explicitly preserves frequency-aware transients while reducing the risk of time-domain ringing artifacts. Building upon these robust neural features, we further introduce a model-agnostic Mid-Feature Semantic Bridge (MFSB) that constructs a regularized intermediate space through directed cross-modal interactions, enabling staged distillation and more stable semantic alignment. Experiments on the THINGS-EEG benchmark show competitive 200-way zero-shot retrieval performance, with 34.50\% Top-1 and 65.95\% Top-5 accuracy. In addition, embeddings learned by STAMBRIDGE produce semantically coherent image reconstructions with a diffusion model, demonstrating robust EEG-to-vision semantic alignment. The code is available at: https://github.com/thabeatmjh/STAMBRIDGE.

eess.IV