ALICE (A Large Ion Collider Experiment) at the CERN Large Hadron Collider (LHC) is designed to study proton-proton and heavy-ion collisions at ultra-relativistic energies. The main goal of the experiment is to assess the properties of quark gluon plasma, a state of matter where quarks and gluons are de-confined, reached in extreme conditions of temperature and energy density. During the ongoing long shutdown 2 of LHC, ALICE is undergoing a major upgrade of its apparatus, in view of the LHC Run 3, scheduled to start in 2022. The upgrade will allow a new ambitious programme of high-precision measurements to be deployed. Moreover, the detectors will have to cope with an increased collision rate, which will go up to 50 kHz in Pb-Pb collisions. For the muon spectrometer (MS) ALICE is implementing new hardware and software solutions. The installation of a new vertex tracker, the Muon Forward Tracker (MFT), in the acceptance of the MS will improve present measurements and enable new ones. It will allow one to separate, for the first time in ALICE in the forward-rapidity region, the prompt and non-prompt contributions to the cross-sections of charmonia. The matching of the muon tracks reconstructed in the MFT with those in the MS will add vertexing capabilities covering a broad range of transverse momenta down to pT = 0 and will improve significantly the invariant mass resolution, allowing for a better separation of the J/psi and psi(2S) states. In addition, the front-end and readout electronics of the muon tracking system (cathode pad chambers) and of the muon identification system (resistive plate chambers) will be upgraded, in order to optimize the detector performance in the new running conditions. A detailed description of the MS upgrades, together with the results from the commissioning with cosmic rays and the first LHC beams, will be presented in this talk.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Livia Terlizzi. 2022-10-22. Upgrade and commissioning of the ALICE muon spectrometer. https://arxiv.org/abs/2210.12431

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det