Search arXivSearch

arXiv · 2211.03307

Three-Dimensionality in the flow of an elastically mounted circular cylinder with two-degree-of-freedom vortex-induced-vibrations

Abstract

The study numerically investigates the three-dimensionality in the flow and two-degree-of-freedom (2 DOF) vortex-induced-vibrations (VIV) characteristics of an elastically mounted circular cylinder. The cylinder is allowed to vibrate in both streamwise and transverse directions. A low value of mass-ratio with the zero damping coefficient is taken for the simulations. The primary aim is to understand the vortex shedding behind the cylinder and the transition characteristics of the wake-flow from two-dimensional (2D) to three-dimensional (3D). The Reynolds number (Re) is varied from 150 (fully 2D flow) to 1000 (fully 3D flow), which lies inside the laminar range. The reduced velocity is varied which covers all three major VIV branches (Initial Branch (IB), Upper Branch (UB), and the Lower Branch (LB)). The oscillating cylinder sweeps the figure-eight trajectory. Two branches (IB, LB) and three branches (IB, UB, LB) amplitude responses are obtained for the low and high Re values, respectively. The wake behind the cylinder with 2-DOF VIV undergoes the mode-C transition of 2D to 3D flow as opposed to the direct mode-B transition observed for transverse only VIV in the literature. The critical Re range of the 2D to 3D transition for the 2-DOF VIV cylinder at a reduced velocity of 6 is around 250, less than the 1-DOF VIV. Also, this range varies with the variation in and the streamwise to transverse oscillation frequency ratio. A map is proposed for the 2-DOF VIV, highlighting the different modes of transition obtained for combinations of reduced frequency and Re.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mayank Verma, Ashoke De. 2022-11-07. Three-Dimensionality in the flow of an elastically mounted circular cylinder with two-degree-of-freedom vortex-induced-vibrations. https://doi.org/10.1063/5.0121944

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mathematical modeling on peristaltic flow of a Prandtl fluid with effects of slip conditions and inclined magnetic field

The manuscript provides a description of a theoretical analysis of a non-Newtonian Prandtl fluid subject to peristaltic flow through an inclined asymmetric channel. We explore the effect of an inclined magnetic field on the peristaltic flow. This is relevant for applications involving fluid flow in narrow, inclined (tilted) tubes similar to blood vessels or the digestive system. The model also includes thermodynamic aspects such as heat diffusion (the Soret effect) and viscous dissipation resulting from wall-fluid slip conditions, which may help optimize medical devices such as lab-on-a-chip systems and dialysis machines. In this study, the concentration of a generic chemical, temperature, and fluid velocity are taken into account through mass, heat, and momentum balances, respectively. The solution is approximated using numerical techniques suitable for long wavelengths (low frequency) and low Reynolds numbers. The study also discusses trapping phenomena, which are crucial from a clinical point of view. The developed insights can improve the understanding of physiological flows in the gastrointestinal tract and blood vessels. By understanding how the fluid moves and how particles are trapped, these insights may contribute to the design of improved medical pumps and artificial organs. Graphical visualizations are provided for the fluid velocity profile, temperature distribution, and concentration of a generic chemical. Furthermore, the numerical results are validated through comparison with a closed-form solution from a benchmark problem.

physics.flu-dyn

Discovery of a dispersion model at high Peclet numbers

Peclet number characterises the transition from classical Taylor-Aris dispersion to convection-dominated longitudinal solute transport, with the classical model becoming inadequate at extremely high radial Peclet number $Pe_r$. We develop a novel explicit-closure one-dimensional (1-D) effective dispersion model for this high-$Pe_r$ regime by introducing two closure coefficients, $θ_u$ and $θ_d$, whose functional structures are identified using low-frequency transfer-function matching and a modified Kolmogorov-Arnold network (KAN). The resulting model captures the transition from classical Taylor-Aris dispersion at low $Pe_r$ to convection-dominated dispersion at high $Pe_r$. Analysis reveals that, in the high-$Pe_r$ regime, axial transport is redistributed between the effective convection flux and the dispersive flux, resulting in a reduced macroscopic convection velocity. Numerical validation demonstrates close agreement with the convection-diffusion model over the investigated high-$Pe_r$ conditions, while the classical Taylor-Aris model exhibits substantial deviations. Application of the proposed model to averaged flow velocity inversion further demonstrates improved velocity estimation, particularly in the high-$Pe_r$ regime. These results highlight the importance of accounting for non-classical dispersion for reliable contrast-agent-based arterial blood flow velocimetry and provide new insight into high-$Pe_r$ mass transport.

physics.flu-dyn

Optimization of fluid mixing by reinforcement learning using limit cycles of a dynamical system

We propose a method to overcome the difficulties encountered when applying reinforcement learning to fluid mixing processes. The proposed method has two main features: (i) it does not require detailed measurements of the flow state, and (ii) by effectively exploiting a stable limit cycle of a two-dimensional dynamical system (the Li'enard system), it can stably perform optimization without imposing explicit constraints on the control parameters. As an illustrative example, we optimize a process in which a fluid contained in a cylindrical vessel is mixed by periodically rotating the vessel. The resulting optimal vessel motion is physically reasonable: it reverses its direction of rotation before a solid-body rotation state is established. Furthermore, even when the fluid viscosity increases with time during the mixing process, the method can continuously adapt the control parameters to the changing viscosity.

physics.flu-dyn