Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c

Abstract

The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.

Explore related subjects

Keep this discovery

BibTeXRIS

B. Acar, G. Adamov, C. Adloff, S. Afanasiev, N. Akchurin, B. Akgün, M. Alhusseini, J. Alison, J. P. Figueiredo de sa Sousa de Almeida, P. G. Dias de Almeida, A. Alpana, M. Alyari, I. Andreev, U. Aras, P. Aspell, I. O. Atakisi, O. Bach, A. Baden, G. Bakas, A. Bakshi, S. Banerjee, P. DeBarbaro, P. Bargassa, D. Barney, F. Beaudette, F. Beaujean, E. Becheva, A. Becker, P. Behera, A. Belloni, T. Bergauer, M. El Berni, M. Besancon, S. Bhattacharya, D. Bhowmik, B. Bilki, S. Bilokin, G. C. Blazey, F. Blekman, P. Bloch, A. Bodek, M. Bonanomi, J. Bonis, A. Bonnemaison, S. Bonomally, J. Borg, F. Bouyjou, N. Bower, D. Braga, L. Brennan, E. Brianne, E. Brondolin, P. Bryant, E. Buhmann, P. Buhmann, A. Butler-Nalin, O. Bychkova, S. Callier, D. Calvet, K. Canderan, K. Cankocak, X. Cao, A. Cappati, B. Caraway, S. Caregari, C. Carty, A. Cauchois, L. Ceard, D. S. Cerci, S. Cerci, G. Cerminara, M. Chadeeva, N. Charitonidis, R. Chatterjee, J. A. Chen, Y. M. Chen, H. J. Cheng, K. Y. Cheng, H. Cheung, D. Chokheli, M. Cipriani, D. Čoko, F. Couderc, E. Cuba, M. Danilov, D. Dannheim, W. Daoud, I. Das, P. Dauncey, G. Davies, O. Davignon, E. Day, P. Debbins, M. M. Defranchis, E. Delagnes, Z. Demiragli, U. Demirbas, G. Derylo, D. Diaz, L. Diehl. 2022-11-09. Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c. https://arxiv.org/abs/2211.04740

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det